Description

Molecular Sieves (CAS 12173-28-3) is a zeolite-type porous aluminosilicate adsorbent supplied in beaded or particulate form. It is a white solid, and the recorded product form is beads or particles rather than a powder or monolith. Its crystalline framework contains uniform pores of molecular dimensions, so the material separates and retains molecules largely by size exclusion and by pore-mouth accessibility rather than by bulk surface area alone. In industrial drying, purification, and selective separation duties, it serves as a regenerable adsorbent for removing water and other small polar molecules from gas and liquid streams.

In packed beds and adsorption columns, Molecular Sieves serves as a regenerable desiccant and selective adsorbent during repeated drying and purification cycles. The resulting dried or purified gas, solvent, or process stream is used in chemical processing, gas handling, and equipment protection duties where moisture control supports stable operation.

Application

  • Gas and air drying: In compressed air, natural gas, and other gas handling systems, Molecular Sieves serves as a regenerable desiccant in packed beds, where its uniform pore structure retains water at low dew points. The resulting dried gas is used where moisture control protects downstream equipment and process reliability.
  • Solvent dehydration: In solvent drying and recovery operations, Molecular Sieves serves as an adsorptive drying medium, where its pore structure takes up water from organic liquid streams. The resulting dried solvent is used in formulation and process operations that require controlled water content.
  • Selective separation of small molecules: In separation duties, Molecular Sieves serves as a size-selective adsorbent, where pore-mouth dimensions discriminate between molecules on the basis of size and shape. The resulting separated fractions are used in gas purification and hydrocarbon processing streams.
  • Protective drying of process streams: In chemical and petrochemical process trains, Molecular Sieves serves as a guard-bed adsorbent, where its water uptake limits moisture carryover to sensitive downstream units. The resulting protected process stream is used where moisture control supports catalyst and equipment performance.
  • Adsorbent for packed-bed and column operations: In fixed-bed and column adsorption systems, Molecular Sieves serves as a granular bed medium, where its bead or particle form supports flow distribution and repeated regeneration cycles. The resulting beds are used in continuous drying and purification service.
  • Moisture control in sealed enclosures: In packaging and enclosure moisture control, Molecular Sieves serves as a desiccant charge, where its adsorption capacity limits humidity around moisture-sensitive contents. The resulting protected enclosure is used for storage and transport of humidity-sensitive materials.

Basic Information

Property Value
Product Name Molecular Sieves
CAS No. 12173-28-3
Molecular Formula UNKNOWN
Molecular Weight UNKNOWN
Physical Beads/particles
Color White
Chemical Property UNKNOWN
Customization Content/concentration customizable per client specification

Quality Control

The quality of Molecular Sieves is governed by its porous crystalline framework, which determines adsorption capacity, selectivity, and regeneration behavior in drying and separation service. Because no product-specific quality focus items were supplied, the points below are general considerations to be defined once identity and specification are confirmed.

Differentiated QC focus Structure, application impact, detection and control
Adsorption capacity Pore volume and accessible pore structure determine how much water or target adsorbate the material can hold before breakthrough. In gas and solvent drying, low capacity shortens bed life and raises regeneration frequency. Capacity should be specified against an agreed test condition and monitored lot to lot.
Pore size and selectivity Framework pore dimensions control which molecules are admitted, so selectivity depends on the grade and its cation form. In selective separation duties, a mismatch in pore size reduces separation efficiency. Pore characteristics should be confirmed against the agreed grade specification.
Bead or particle integrity Mechanical strength and attrition resistance affect pressure drop and fines generation in packed beds. In column operation, weak particles can crush or dust, causing channeling and carryover. Integrity should be checked by agreed attrition and crush-strength methods.
Moisture content as supplied Residual water occupies adsorption sites before use and reduces available capacity. In drying service, pre-loaded moisture shortens the working cycle. As-supplied moisture should be controlled and checked before charging to a bed.
Regeneration behavior Repeated thermal cycling can degrade capacity and structure over service life. In cyclic drying operations, loss of regenerability shortens adsorbent life. Regeneration conditions and capacity retention should be agreed and verified.

Batch release, COA and traceability. Each batch is released only when it conforms to the agreed specification. The Certificate of Analysis (COA) records the actual analytical methods and results for that released batch. Batch identity and results remain traceable, with lot trending used where it supports consistency review.

Storage

  • Storage conditions: Store in a cool, dry, well-ventilated area. Keep containers closed when not in use to limit uptake of atmospheric moisture.
  • Secure storage: Store in a secure, designated area with access limited to authorized personnel.
  • Incompatible materials: Keep away from strong acids and other materials that could attack the aluminosilicate framework.
  • Handling precautions: Avoid generating and breathing dust. Use in a well-ventilated area. Wear protective gloves, protective clothing, and eye protection. Wash hands thoroughly after handling.
  • Waste disposal: Dispose of contents and container in accordance with local, regional, national, and international regulations.
  • Reference: Refer to the Safety Data Sheet (SDS) for detailed handling and disposal information.

Complete Your RFQ

0/ 2000

why choose us

Trusted Manufacturer

With our own production facilities, we ensure consistent quality, reliable supply, and full traceability.

Rigorous Quality Assurance

Each batch undergoes strict QC, accompanied by COA, MSDS, and full compliance with international standards.

Advanced R&D Expertise

Our in-house lab drives process innovation, new product development, and tailored synthesis solutions.