share

Molecular Sieve CAS NO 1344-00-9


Unit Price:

CAS No.:1344-00-9

Grade:Customizable

Content:Customizable

Brand:Customizable

Packaging:Customizable

Description

Molecular Sieve (CAS 1344-00-9) is a synthetic zeolite-type adsorbent supplied in bead or particle form. It is a white, porous, crystalline aluminosilicate material whose framework contains uniform pores of molecular dimensions. Its rigid three-dimensional zeolite framework carries exchangeable cations and a high internal surface area, which supports selective adsorption of small molecules on the basis of size and polarity. In industrial drying, gas and liquid purification, and selective separation processes, it serves as a regenerable desiccant and adsorbent for moisture removal and molecular-level separation.

In desiccant beds, drying cartridges, and adsorption columns, Molecular Sieve is charged as a regenerable adsorbent medium during repeated drying and purification cycles. The resulting dried gases, solvents, and sealed assemblies are used in industrial gas handling, chemical processing, and insulating glass units for moisture control and protection against condensation.

Application

  • Industrial gas drying: In compressed air, natural gas, and process gas handling, Molecular Sieve serves as a regenerable desiccant in adsorption dryers, where its uniform pore structure contributes to deep moisture removal. The resulting dried gas is used in instrument air, pipeline transport, and downstream processing.
  • Solvent and liquid drying: In solvent purification and liquid handling, Molecular Sieve serves as an adsorbent for trace water removal, where its porous framework contributes to low residual moisture. The resulting dried liquids are used in formulation, reaction, and processing operations.
  • Selective separation of small molecules: In adsorption-based separation, Molecular Sieve serves as a size-selective adsorbent, where its uniform pore openings contribute to discrimination between molecules of different size or polarity. The resulting separated streams are used in gas purification and recovery processes.
  • Insulating glass and sealed-unit drying: In insulating glass and sealed assembly manufacture, Molecular Sieve serves as a desiccant fill, where its moisture uptake contributes to preventing internal condensation. The resulting sealed units are used in building glazing and thermal insulation.
  • Catalyst support and adsorbent media: In catalyst and adsorbent formulation, Molecular Sieve serves as a porous support or active adsorbent component, where its high internal surface area and exchangeable cations contribute to dispersion and adsorption function. The resulting media are used in industrial catalytic and purification systems.
  • Packaging and enclosure moisture control: In packaging and enclosed equipment, Molecular Sieve serves as a moisture-scavenging desiccant, where its adsorption capacity contributes to limiting humidity during storage and transport. The resulting protected goods are used in electronics, instruments, and moisture-sensitive products.

Basic Information

Property Value
Product Name Molecular Sieve
CAS No. 1344-00-9
Molecular Formula UNKNOWN
Molecular Weight UNKNOWN
Physical Beads/particles
Color White
Chemical Property UNKNOWN
Customization Content/concentration customizable per client specification

Quality Control

The quality of Molecular Sieve is governed by its porous zeolite framework, whose pore size, crystallinity, and cation content determine adsorption capacity, selectivity, and regeneration behavior in drying and separation service.

Differentiated QC focus Structure, application impact, detection and control
Pore size and framework type The uniform pore openings of the zeolite framework determine which molecules are adsorbed. In gas drying and selective separation, a mismatched pore size can reduce capacity or allow co-adsorption of unwanted species. Confirm framework type and pore opening against the agreed specification, and verify by X-ray diffraction and nitrogen adsorption.
Adsorption capacity Equilibrium water uptake reflects the available pore volume and cation state. In desiccant beds and sealed units, low capacity shortens service life and increases regeneration frequency. Set an agreed water adsorption capacity limit and check by gravimetric moisture uptake at controlled humidity.
Crystallinity and phase purity Amorphous content or secondary phases reduce effective pore volume and selectivity. In separation and drying service, impurities can cause variable breakthrough behavior. Monitor by X-ray diffraction and compare patterns against the agreed reference.
Bead or particle integrity Mechanical strength and attrition resistance affect pressure drop and dust generation in packed beds. In adsorption columns, fines can cause channeling and carryover. Assess crush strength and attrition according to agreed methods.
Moisture content as supplied Residual water in the delivered material reduces available capacity and can affect sealed-unit performance. In packaging and drying applications, pre-loaded moisture shortens working life. Determine loss on drying or water content by agreed gravimetric methods.
Cation content and exchange level Exchangeable cations influence polarity and adsorption selectivity. In selective separation, an off-specification cation level can shift selectivity. Confirm cation type and exchange level against the agreed specification where relevant.

Batch release, COA and traceability. Each batch is released only when it conforms to the agreed specification. The Certificate of Analysis (COA) records the actual analytical methods and results for that released batch. Batch identity and results remain traceable, with lot trending used where it supports consistency review.

Storage

  • Storage conditions: Store in a dry, well-ventilated area with containers kept closed to limit moisture uptake from ambient air.
  • Secure storage: Store in a designated area with access limited to authorized personnel.
  • Incompatible materials: Keep separate from materials that could contaminate the adsorbent or degrade the container.
  • Handling precautions: Avoid generating or breathing dust. Use in a well-ventilated area. Wear protective gloves, protective clothing, and eye protection. Wash hands after handling.
  • Waste disposal: Dispose of contents and container in accordance with local, regional, national, and international regulations.
  • Reference: Refer to the Safety Data Sheet (SDS) for detailed handling and disposal information.

Complete Your RFQ

0/ 2000

why choose us

Trusted Manufacturer

With our own production facilities, we ensure consistent quality, reliable supply, and full traceability.

Rigorous Quality Assurance

Each batch undergoes strict QC, accompanied by COA, MSDS, and full compliance with international standards.

Advanced R&D Expertise

Our in-house lab drives process innovation, new product development, and tailored synthesis solutions.