Description

Ammonium Hexachloroiridate(IV) (CAS 16940-92-4) is an ammonium salt of the hexachloroiridate(IV) anion, in which iridium is present in the +4 oxidation state coordinated by six chloride ligands. It is recorded as a black, crystalline granular solid. The compound is a discrete coordination salt rather than a polymeric material, and its iridium centre is held in a relatively high oxidation state within a chloride-rich coordination sphere. In precious-metal catalyst preparation and coordination chemistry, it serves as a well-defined, weighable source of chlorido-coordinated iridium for the construction of iridium-containing catalytic and coordination compounds.

In precious-metal catalyst preparation, Ammonium Hexachloroiridate(IV) serves as a soluble-in-principle iridium source during batch dissolution, ligand exchange and subsequent isolation steps, where the hexachloroiridate(IV) anion supplies iridium in a defined oxidation state and chloride coordination environment. The resulting iridium compounds and supported catalyst materials are used in catalyst screening, electrode modification and specialty coordination chemistry work where a controlled iridium starting material is required.

Application

  • Precious-metal catalyst preparation: In precious-metal catalyst preparation, Ammonium Hexachloroiridate(IV) serves as a defined iridium source, where its hexachloroiridate(IV) anion provides iridium in the +4 oxidation state with chloride ligands that can be displaced or retained during downstream chemistry. The resulting iridium compounds are used in catalyst preparation and screening for oxidation and electrochemical reactions.
  • Coordination chemistry research: In coordination chemistry research, Ammonium Hexachloroiridate(IV) serves as a starting chlorido iridium complex, where its [IrCl6]2- anion provides a structurally defined octahedral iridium centre for ligand substitution and speciation studies. The resulting complexes are used to examine redox behaviour and ligand-exchange pathways of iridium.
  • Electrode and surface modification research: In electrode and surface modification research, Ammonium Hexachloroiridate(IV) may be evaluated as an iridium deposition source, where its chlorido iridium anion can be converted to iridium-containing films or surface species under controlled conditions. The resulting modified surfaces are examined for electrochemical and catalytic behaviour.
  • Chlorido iridium complex synthesis: In chlorido iridium complex synthesis, Ammonium Hexachloroiridate(IV) serves as a convenient ammonium salt of the hexachloroiridate(IV) anion, where the ammonium counter-ion and chloride ligands allow salt metathesis and ligand substitution routes. The resulting iridium complexes are used in specialty coordination and materials chemistry studies.
  • Analytical and reference use in iridium chemistry: In analytical and reference work on iridium chemistry, Ammonium Hexachloroiridate(IV) may be evaluated as a defined iridium standard compound, where its known anion composition supports gravimetric and spectroscopic iridium determinations. This is a laboratory evaluation context.

Basic Information

Property Value
Product Name Ammonium Hexachloroiridate(IV)
CAS No. 16940-92-4
Molecular Formula UNKNOWN
Molecular Weight 481.01 g/mol
Physical Crystalline granules
Color Black
Chemical Property UNKNOWN
Customization Content/concentration customizable per client specification

Quality Control

The quality of Ammonium Hexachloroiridate(IV) is governed by its identity as an ammonium salt of the hexachloroiridate(IV) anion, so iridium content, oxidation state and chloride coordination are the central quality concerns for catalyst and coordination chemistry use.

Differentiated QC focus Structure, application impact, detection and control
Iridium content and assay The hexachloroiridate(IV) anion carries the iridium value of the product, and iridium content directly determines how much active metal is delivered in catalyst preparation. Low iridium content dilutes the starting material and shifts catalyst loading; high or variable content complicates stoichiometric use. Set an agreed specification range for iridium content and qualify incoming lots against it. Test by gravimetric determination after reduction and precipitation, or by ICP-OES/ICP-MS after suitable dissolution.
Oxidation state of iridium The product is defined by iridium in the +4 state; partial reduction or oxidation changes the anion and its downstream reactivity. In coordination and catalyst work, a shifted oxidation state can alter ligand substitution behaviour and the properties of the resulting iridium species. Control by handling and storage that limits redox-active contact, and check the oxidation state where the application requires it. Test by UV-Vis spectrophotometry of the chlorido iridium anion or by electrochemical methods.
Chloride coordination and anion identity The six chloride ligands define the octahedral [IrCl6]2- anion; incomplete chloridation or hydrolysis gives different species. In ligand-substitution chemistry, altered chloride coordination changes the reactivity and the products obtained. Set identity checks on the anion and control exposure to water during handling. Test by FTIR and UV-Vis spectroscopy, and by elemental chloride determination where required.
Ammonium counter-ion content The ammonium counter-ion balances the dianion; its level affects the salt stoichiometry and the mass of iridium delivered per unit weight. In metathesis and dissolution steps, counter-ion variation changes solubility behaviour and the iridium fraction. Set an agreed range for ammonium content and check it against the iridium assay. Test by ion chromatography or by titration of ammonia released under alkaline conditions.
Moisture and hygroscopic behaviour The salt is recorded as hygroscopic in the source description; absorbed water changes weighing accuracy and can promote hydrolysis of the chlorido anion. In catalyst preparation, moisture causes weighing errors and can introduce hydrolysis products into the reaction. Control by tight-closure packaging and handling under dry conditions, and set a limit on water content. Test by Karl Fischer titration or loss on drying.
Insoluble matter and foreign particulates Undissolved residue or particulates can arise from incomplete reaction or handling and remain in solution during catalyst preparation. In solution-based catalyst work, insoluble matter can cause turbidity, clogging and inconsistent metal delivery. Include filtration where a clear solution is required and inspect lots intended for solution use. Test by gravimetric determination of insoluble matter after dissolution.
Appearance and homogeneity The product is recorded as black crystalline granules; colour and granule uniformity are practical indicators of lot consistency. In weighing and dispensing, non-uniform material complicates subsampling and can bias small-scale catalyst experiments. Set agreed appearance criteria and inspect lots against them. Test by visual comparison against an agreed reference.

Batch release, COA and traceability. Each batch is released only when it conforms to the agreed specification. The Certificate of Analysis (COA) records the actual analytical methods and results for that released batch. Batch identity and results remain traceable, with lot trending used where it supports consistency review.

Storage

  • Storage conditions: Store in a cool, dry, well-ventilated area. Keep containers tightly closed when not in use and protect from light.
  • Secure storage: Store in a secure, designated area with access limited to authorized personnel.
  • Incompatible materials: Keep away from strong oxidizing and reducing agents and from sources of moisture.
  • Handling precautions: Avoid breathing dust. Use only in a well-ventilated area. Wear protective gloves, protective clothing, eye protection, and face protection. Wash hands thoroughly after handling.
  • Waste disposal: Dispose of contents and container in accordance with local, regional, national, and international regulations.
  • Reference: Refer to the Safety Data Sheet (SDS) for detailed handling and disposal information.

Complete Your RFQ

0/ 2000

why choose us

Trusted Manufacturer

With our own production facilities, we ensure consistent quality, reliable supply, and full traceability.

Rigorous Quality Assurance

Each batch undergoes strict QC, accompanied by COA, MSDS, and full compliance with international standards.

Advanced R&D Expertise

Our in-house lab drives process innovation, new product development, and tailored synthesis solutions.