share

Platinum(Ii)-Ammonium Chloride CAS NO 13820-41-2


Unit Price:

CAS No.:13820-41-2

Grade:Customizable

Content:Customizable

Brand:Customizable

Packaging:Customizable

Description

Platinum(II)-Ammonium Chloride (CAS 13820-41-2) is a platinum(II) ammonium chloride coordination compound, recorded in the source database as a yellow solid. It is a water-soluble ionic platinum salt in which the platinum center is coordinated by chloride ligands and charge-balanced by ammonium cations. Its platinum(II) center and labile chloride coordination sphere support ligand-exchange and reduction chemistry, giving it the role of a platinum source in coordination and catalyst preparation systems. In precious-metal catalyst preparation and coordination chemistry work, it serves as a platinum-containing starting material for the construction of supported and homogeneous platinum species.

In catalyst preparation and coordination chemistry workflows, Platinum(II)-Ammonium Chloride serves as a soluble platinum source during batch dissolution, impregnation or ligand-exchange steps. The resulting platinum-containing solutions, supported compounds or coordination compounds are used in catalyst development and precious-metal material preparation for platinum loading and ligand environment control.

Application

  • Precious-metal catalyst preparation: In precious-metal catalyst preparation, Platinum(II)-Ammonium Chloride serves as a soluble platinum(II) source, where its chloride-coordinated platinum center contributes to the formation of active platinum species on supports or in solution. The resulting platinum-containing materials are used in catalyst development for precious-metal loading.
  • Supported catalyst impregnation: In supported catalyst impregnation, Platinum(II)-Ammonium Chloride serves as an aqueous platinum starting material solution component, where its solubility allows distribution of platinum onto oxidic or carbon supports. The resulting impregnated material is used in catalyst manufacturing development for dispersed platinum sites.
  • Coordination chemistry research: In coordination chemistry research, Platinum(II)-Ammonium Chloride may be evaluated as a platinum(II) chloride complex, where its labile chloride ligands support ligand-substitution studies. This work supports the design of platinum coordination compounds.
  • Platinum salt preparation: In platinum salt preparation, Platinum(II)-Ammonium Chloride serves as an compound platinum(II) source, where its ammonium and chloride components allow conversion to other platinum salts by ion exchange or ligand substitution. The resulting platinum salts are used in further coordination and materials work.
  • Electroless and electroplating bath development: In plating bath development, Platinum(II)-Ammonium Chloride may be evaluated as a soluble platinum(II) source, where its chloride coordination contributes to platinum ion supply in aqueous systems. This is a development-stage evaluation context.

Basic Information

Property Value
Product Name Platinum(Ii)-Ammonium Chloride
CAS No. 13820-41-2
Molecular Formula UNKNOWN
Molecular Weight 372.99 g/mol
Physical Solid
Color Yellow
Chemical Property UNKNOWN
Customization Content/concentration customizable per client specification

Quality Control

The quality of Platinum(II)-Ammonium Chloride is governed by its platinum content and coordination environment, which directly affect the performance of platinum species formed in catalyst and coordination applications. Because no product-specific quality focus items were supplied, the points below are general guidance to be defined after identity and specification confirmation.

Differentiated QC focus Structure, application impact, detection and control
Platinum content The platinum(II) center determines the active-metal loading delivered to catalyst or coordination systems. Low platinum content reduces loading efficiency, while inconsistent content causes variable catalyst performance. Platinum content should be specified and controlled, with raw-material qualification and lot trending. Platinum is commonly determined by ICP-OES or ICP-MS after appropriate sample preparation.
Identity and coordination form The chloride-coordinated platinum(II) ammonium salt determines solubility and ligand-exchange behavior. A different coordination form or oxidation state can alter reactivity and downstream catalyst formation. Identity should be confirmed against an agreed specification. Platinum coordination salts are commonly characterized by UV-Vis spectroscopy, FTIR and elemental analysis.
Ammonium and chloride content The ammonium cations and chloride ligands balance the complex and affect dissolution and ion-exchange behavior. Deviations can shift solubility or introduce competing ions. These should be specified where the application requires and monitored by ion chromatography or titration.
Moisture and volatiles Residual moisture or volatiles can affect weighing accuracy, solution preparation and storage stability. They should be limited according to an agreed specification and checked by loss-on-drying or Karl Fischer titration where appropriate.
Appearance The product is recorded as a yellow solid; color change can indicate oxidation, hydrolysis or contamination. Appearance should be compared against an agreed reference standard.
Trace impurities Residual base metals or other platinum-group metals can affect catalyst selectivity. Impurity limits should be set where the application requires and checked by ICP-OES or ICP-MS.

Batch release, COA and traceability. Each batch is released only when it conforms to the agreed specification. The Certificate of Analysis (COA) records the actual analytical methods and results for that released batch. Batch identity and results remain traceable, with lot trending used where it supports consistency review.

Storage

  • Storage conditions: Store in a cool, dry, well-ventilated area. Keep containers tightly closed when not in use. Protect from light.
  • Secure storage: Store in a secure, designated area with access limited to authorized personnel.
  • Incompatible materials: Keep away from strong oxidizers and incompatible chemicals.
  • Handling precautions: Avoid breathing dust or mist. Use only in a well-ventilated area. Wear protective gloves, protective clothing, eye protection, and face protection. Wash hands thoroughly after handling.
  • Waste disposal: Dispose of contents and container in accordance with local, regional, national, and international regulations.
  • Reference: Refer to the Safety Data Sheet (SDS) for detailed handling and disposal information.

Complete Your RFQ

0/ 2000

why choose us

Trusted Manufacturer

With our own production facilities, we ensure consistent quality, reliable supply, and full traceability.

Rigorous Quality Assurance

Each batch undergoes strict QC, accompanied by COA, MSDS, and full compliance with international standards.

Advanced R&D Expertise

Our in-house lab drives process innovation, new product development, and tailored synthesis solutions.