share

Platinum(Iv) Oxide Hydrate CAS NO 12137-21-2


Unit Price:

CAS No.:12137-21-2

Grade:Customizable

Content:Customizable

Brand:Customizable

Packaging:Customizable

Description

Platinum(IV) Oxide Hydrate (CAS 12137-21-2) is a hydrated platinum(IV) oxide, a platinum dioxide material carrying variable water content. It is a black solid and is generally described as sparingly soluble in water and common organic solvents. Its platinum(IV) oxide framework provides an oxidatively active platinum surface, giving it the role of a precious-metal oxidation catalyst in catalytic and electrochemical material systems. In oxidation catalysis and electrode material preparation, it serves as a platinum-based active component for oxidation and electron-transfer functions.

In catalyst preparation and electrode material manufacturing, Platinum(IV) Oxide Hydrate serves as a platinum source and active oxide component during batch formulation and repeated production of catalytic and electrochemical materials. The resulting catalysts and electrode components are used in chemical processing, emissions-related oxidation, and electrochemical devices for oxidation and electron-transfer functions.

Application

  • Oxidation catalysis: In oxidation catalysis, Platinum(IV) Oxide Hydrate serves as a platinum-based oxidation catalyst, where its platinum(IV) oxide surface contributes to oxidation of organic and inorganic substrates. The resulting catalyst is used in chemical processing for selective oxidation steps.
  • Hydrogenation and reduction catalysis: In hydrogenation and reduction catalysis, Platinum(IV) Oxide Hydrate serves as a platinum catalyst precursor or active component, where the platinum oxide is reduced to finely divided platinum metal that contributes to hydrogen addition and reduction reactions. The resulting catalyst is used in fine chemical and laboratory hydrogenation processes.
  • Electrode and electrochemical materials: In electrode and electrochemical material preparation, Platinum(IV) Oxide Hydrate serves as a platinum oxide component, where its redox-active platinum centers contribute to electrochemical oxidation and charge-transfer behavior. The resulting electrode materials are used in electrochemical devices and sensing electrodes.
  • Catalytic oxidation in emissions and gas treatment: In catalytic oxidation for gas treatment, Platinum(IV) Oxide Hydrate serves as a platinum oxide active phase, where its platinum surface contributes to oxidation of carbon monoxide and volatile organic compounds. The resulting catalyst is used in emissions-related and process gas purification systems.
  • Platinum catalyst preparation: In platinum catalyst preparation, Platinum(IV) Oxide Hydrate serves as a platinum source for supported and unsupported catalyst fabrication, where its platinum content contributes to dispersion and active-site formation on catalyst supports. The resulting catalysts are used in industrial and laboratory catalytic processes.
  • Analytical and reference applications: In analytical and reference applications, Platinum(IV) Oxide Hydrate serves as a platinum reference compound, where its defined platinum oxidation state contributes to calibration and method development work. The resulting reference materials are used in analytical laboratories.

Basic Information

Property Value
Product Name Platinum(IV) Oxide Hydrate
CAS No. 12137-21-2
Molecular Formula UNKNOWN
Molecular Weight 227.08 (anhydrous basis) + xH₂O
Physical Solid
Color Black
Chemical Property UNKNOWN
Customization Content/concentration customizable per client specification

Quality Control

The quality of Platinum(IV) Oxide Hydrate is governed by its platinum content, oxidation state, and hydration level, which directly affect catalytic activity and electrochemical performance in oxidation, hydrogenation, and electrode applications.

Differentiated QC focus Structure, application impact, detection and control
Platinum content Platinum content determines the active-metal loading available for catalysis. In oxidation and hydrogenation catalysis, low platinum content reduces activity per unit mass, while high or variable content affects dosing and cost calculations. Set an agreed specification range for platinum content and qualify incoming lots against it. Test by gravimetric analysis after reduction or by ICP-OES/ICP-MS after appropriate dissolution.
Oxidation state and phase composition The material is a platinum(IV) oxide hydrate; residual lower oxides or metallic platinum can alter redox behavior. In oxidation catalysis and electrode applications, phase composition affects activity and charge-transfer behavior. Control by qualified preparation and lot comparison. Test by X-ray diffraction for phase identification and by XPS or titration for oxidation-state assessment where applicable.
Hydration level and water content Variable water content is intrinsic to the hydrate and affects platinum content on an as-received basis and dispersion behavior. In catalyst preparation, inconsistent hydration changes effective platinum loading and slurry behavior. Set specification limits on water content or loss on drying and report results on a defined basis. Test by thermogravimetric analysis or loss-on-drying.
Particle size and surface area Particle size and specific surface area influence dispersion and accessible active surface. In catalytic oxidation and electrode fabrication, low surface area reduces activity, while agglomeration causes uneven dispersion. Control by agreed particle-size and surface-area ranges and by dispersion checks. Test by laser diffraction or sieving and by BET surface-area measurement.
Trace impurities Residual chloride, base-metal impurities, or processing residues can poison catalysts or affect electrochemical behavior. In hydrogenation and electrode applications, chloride and sulfur species can deactivate platinum sites. Qualify raw materials and set limits on key impurities. Test by ICP-OES/ICP-MS for metals and by ion chromatography for chloride where relevant.
Appearance and homogeneity The product is described as a black solid; color variation or inhomogeneity can indicate phase or hydration differences. In catalyst and electrode preparation, inhomogeneous lots cause inconsistent dispersion and activity. Inspect lots visually against an agreed standard and check homogeneity before sampling. Test by visual comparison and by sampling from multiple positions.

Batch release, COA and traceability. Each batch is released only when it conforms to the agreed specification. The Certificate of Analysis (COA) records the actual analytical methods and results for that released batch. Batch identity and results remain traceable, with lot trending used where it supports consistency review.

Storage

  • Storage conditions: Store in a cool, dry, well-ventilated area. Keep containers tightly closed when not in use.
  • Secure storage: Store in a secure, designated area with access limited to authorized personnel.
  • Incompatible materials: Keep away from strong reducing agents and combustible organic materials.
  • Handling precautions: Avoid breathing dust. Use only in a well-ventilated area. Wear protective gloves, protective clothing, eye protection, and face protection. Wash hands thoroughly after handling.
  • Waste disposal: Dispose of contents and container in accordance with local, regional, national, and international regulations.
  • Reference: Refer to the Safety Data Sheet (SDS) for detailed handling and disposal information.

Complete Your RFQ

0/ 2000

why choose us

Trusted Manufacturer

With our own production facilities, we ensure consistent quality, reliable supply, and full traceability.

Rigorous Quality Assurance

Each batch undergoes strict QC, accompanied by COA, MSDS, and full compliance with international standards.

Advanced R&D Expertise

Our in-house lab drives process innovation, new product development, and tailored synthesis solutions.