Description

Palladium Hydroxide (CAS 12135-22-7) is a palladium compound supplied as a solid. It is a black solid and is generally described as sparingly soluble in water, with solubility behavior depending on the form and history of the material. Its palladium center in a hydroxide environment supports redox and catalytic chemistry, giving it the role of a precious-metal catalyst or catalyst building block in hydrogenation, oxidation, and related catalytic systems. In precious-metal catalyst preparation and catalytic hydrogenation and oxidation processes, it serves as a palladium source for catalyst formulation and reaction screening.

In catalyst preparation and catalytic reaction systems, Palladium Hydroxide serves as a palladium-bearing catalyst component or starting material material during catalyst formulation and batch preparation. The resulting palladium catalysts are used in hydrogenation, oxidation, and related catalytic transformations in fine chemical and materials processing applications.

Application

  • Catalytic hydrogenation: In catalytic hydrogenation, Palladium Hydroxide serves as a palladium catalyst or catalyst component, where its palladium centers contribute to hydrogen activation and reduction of unsaturated substrates. The resulting hydrogenated products are used in fine chemical and materials processing.
  • Catalytic oxidation: In catalytic oxidation, Palladium Hydroxide serves as a palladium-based catalyst component, where its palladium centers participate in oxygen or oxidant activation. The resulting oxidized products are used in chemical and materials synthesis.
  • Precious-metal catalyst preparation: In precious-metal catalyst preparation, Palladium Hydroxide serves as a palladium source for supported or unsupported catalyst formulation, where its palladium content contributes to the active phase. The resulting catalysts are used in hydrogenation and oxidation processes.
  • Catalyst screening and evaluation: In catalyst screening and evaluation, Palladium Hydroxide may be evaluated as a palladium reference compound, where its palladium chemistry supports comparative catalytic studies. This is a laboratory evaluation context.
  • Palladium chemistry research: In palladium chemistry research, Palladium Hydroxide may be examined as a palladium hydroxide species, where its composition supports studies of palladium redox and coordination behavior. This is a research context.

Basic Information

Property Value
Product Name Palladium Hydroxide
CAS No. 12135-22-7
Molecular Formula UNKNOWN
Molecular Weight 140.43 g/mol
Physical Solid
Color Black
Chemical Property UNKNOWN
Customization Content/concentration customizable per client specification

Quality Control

The quality of Palladium Hydroxide is governed by its palladium content and the form of the palladium species, which directly affect catalytic activity and consistency in hydrogenation and oxidation applications. Because no product-specific quality focus items were supplied, the points below are general guidance to be confirmed once identity and specifications are established.

Differentiated QC focus Structure, application impact, detection and control
Palladium content Palladium content determines the active metal available for catalysis. In hydrogenation and oxidation, low palladium content reduces activity, while variability between lots can shift conversion and selectivity. Palladium content should be confirmed against an agreed specification, with raw materials qualified and results trended. Palladium is commonly determined by ICP-OES or ICP-MS after suitable sample digestion.
Palladium speciation and form The palladium species and its degree of hydration or oxidation state can influence catalyst activation and behavior. Differences in speciation may change induction periods or activity in hydrogenation and oxidation. The palladium species should be characterized where the application requires it, using techniques such as X-ray diffraction or spectroscopic methods, and correlated with catalytic performance.
Residual chloride and anions Residual anions from preparation can remain in the material and may affect catalyst performance or corrode equipment. In catalytic applications, residual chloride can influence activity and selectivity. Anion content should be controlled against an agreed limit, with ion chromatography or titration used where appropriate.
Moisture and volatile matter Moisture and volatiles can affect weighing, dispersion, and catalyst activation behavior. In catalyst preparation, variable moisture can change the effective palladium charge and reproducibility. Moisture should be controlled and monitored, for example by loss-on-drying or Karl Fischer titration where appropriate.
Particle and aggregate characteristics Particle size and aggregation influence dispersion and accessible surface in catalyst preparation. In slurry or supported catalyst systems, coarse or aggregated material can cause uneven dispersion and inconsistent activity. Particle characteristics should be assessed where relevant, using sieving, laser diffraction, or microscopy.
Appearance and foreign matter The material is described as a black solid; visible foreign matter or inhomogeneity can indicate contamination or inconsistent preparation. In catalyst use, contaminants can poison active sites. Visual inspection and appropriate cleanliness controls should be applied, with foreign matter examined where observed.

Batch release, COA and traceability. Each batch is released only when it conforms to the agreed specification. The Certificate of Analysis (COA) records the actual analytical methods and results for that released batch. Batch identity and results remain traceable, with lot trending used where it supports consistency review.

Storage

  • Storage conditions: Store in a cool, dry, well-ventilated area. Keep containers tightly closed when not in use.
  • Secure storage: Store in a secure, designated area with access limited to authorized personnel.
  • Incompatible materials: Keep away from strong oxidizers and incompatible chemicals.
  • Handling precautions: Avoid breathing dust. Use only in a well-ventilated area. Wear protective gloves, protective clothing, eye protection, and face protection. Wash hands thoroughly after handling.
  • Waste disposal: Dispose of contents and container in accordance with local, regional, national, and international regulations.
  • Reference: Refer to the Safety Data Sheet (SDS) for detailed handling and disposal information.

Complete Your RFQ

0/ 2000

why choose us

Trusted Manufacturer

With our own production facilities, we ensure consistent quality, reliable supply, and full traceability.

Rigorous Quality Assurance

Each batch undergoes strict QC, accompanied by COA, MSDS, and full compliance with international standards.

Advanced R&D Expertise

Our in-house lab drives process innovation, new product development, and tailored synthesis solutions.