share

1,1-Bis(T-Hexylperoxy)-3,3,5-Trimethyl Cyclohexane CAS NO 104066-39-9


Unit Price:

CAS No.:104066-39-9

Grade:Customizable

Content:Customizable

Brand:Customizable

Packaging:Customizable

Description

1,1-Bis(T-Hexylperoxy)-3,3,5-Trimethyl Cyclohexane (CAS 104066-39-9) is a cyclohexane derivative bearing two hexylperoxy groups on the same ring carbon, placing it in the dialkyl peroxide class of organic peroxides. It is recorded as a liquid and is described as colorless. As a dialkyl peroxide, its peroxy bonds are thermally labile and can undergo homolytic cleavage to generate alkoxyl radicals, which is the basis for its role as a radical-generating component in initiated chemical systems. In polymer and resin processing, such peroxides serve as radical sources for initiating polymerization and crosslinking reactions.

In polymerization and crosslinking processes, 1,1-Bis(T-Hexylperoxy)-3,3,5-Trimethyl Cyclohexane serves as a thermally activated radical source during batch or continuous resin processing. The radicals formed on decomposition initiate chain growth or network formation, and the resulting polymers and cured materials are used in industrial plastics, elastomer and coating applications where controlled radical initiation is required.

Application

  • Radical polymerization initiation: In polymerization processes, 1,1-Bis(T-Hexylperoxy)-3,3,5-Trimethyl Cyclohexane serves as a thermal radical initiator, where its peroxy groups decompose to generate radicals that start monomer chain growth. The resulting polymers are used in industrial plastics and resin manufacturing.
  • Crosslinking initiation: In crosslinking processes, 1,1-Bis(T-Hexylperoxy)-3,3,5-Trimethyl Cyclohexane serves as a radical source, where peroxy decomposition contributes to the formation of interchain covalent bonds. The resulting crosslinked materials are used in elastomer and thermoset components.
  • Curing initiation: In curing systems, 1,1-Bis(T-Hexylperoxy)-3,3,5-Trimethyl Cyclohexane serves as a thermal initiator, where its decomposition radicals contribute to the conversion of reactive resin formulations into cured networks. The resulting cured products are used in industrial coating and composite fabrication.
  • Peroxide formulation research: In peroxide formulation research, 1,1-Bis(T-Hexylperoxy)-3,3,5-Trimethyl Cyclohexane may be evaluated as a dialkyl peroxide model compound, where its dual peroxy functionality supports studies of decomposition kinetics and radical generation. This is a research evaluation context.

Basic Information

Property Value
Product Name 1,1-Bis(T-Hexylperoxy)-3,3,5-Trimethyl Cyclohexane
CAS No. 104066-39-9
Molecular Formula UNKNOWN
Molecular Weight 342.52 g/mol
Physical Liquid
Color Colorless
Chemical Property UNKNOWN
Customization Content/concentration customizable per client specification

Quality Control

The quality of 1,1-Bis(T-Hexylperoxy)-3,3,5-Trimethyl Cyclohexane is governed by its peroxy content and thermal stability, which directly affect its performance as a radical initiator in polymerization, crosslinking and curing systems.

Differentiated QC focus Structure, application impact, detection and control
Active oxygen and peroxy content The two hexylperoxy groups on the cyclohexane ring are the functional sites that generate radicals on decomposition. In polymerization and crosslinking, low active oxygen means insufficient radical generation and incomplete conversion, while excessive or variable content can cause runaway decomposition or premature reaction. Set an agreed specification range for active oxygen or peroxy content and qualify incoming material against it. Test by iodometric titration for active oxygen.
Thermal decomposition profile Peroxy bond cleavage is temperature-dependent and determines the initiation temperature window. In curing and polymerization, a shifted decomposition profile can cause under-cure at the intended process temperature or premature decomposition during storage and handling. Characterize decomposition behavior and set agreed temperature limits for processing and storage. Test by differential scanning calorimetry or thermal decomposition studies.
Purity and organic impurities Residual starting materials or by-products from peroxide preparation can affect radical yield and reaction reproducibility. In resin and elastomer processing, impurities can alter cure rate or cause discoloration. Set specification limits on principal impurities and monitor lot-to-lot consistency. Test by gas chromatography or liquid chromatography where a suitable method is available.
Moisture Water content can affect peroxide stability and, in some formulations, cause phase separation or inconsistent decomposition. In polymerization systems, moisture can influence reaction rate and product quality. Set an agreed water limit and use moisture-controlled packaging. Test by Karl Fischer titration.
Appearance The product is recorded as a colorless liquid; color or haze can indicate decomposition, contamination or aging. In clear coatings and resins, color development can affect final product appearance. Set agreed color and clarity limits and protect from light and heat. Test by visual comparison or colorimetry.

Batch release, COA and traceability. Each batch is released only when it conforms to the agreed specification. The Certificate of Analysis (COA) records the actual analytical methods and results for that released batch. Batch identity and results remain traceable, with lot trending used where it supports consistency review.

Storage

  • Storage conditions: Store in a cool, dry, well-ventilated area away from heat and direct sunlight. Keep containers tightly closed when not in use.
  • Secure storage: Store in a secure, designated area with access limited to authorized personnel.
  • Incompatible materials: Keep away from strong acids, strong bases, reducing agents and combustible materials.
  • Handling precautions: Avoid breathing vapors or mist. Use only in a well-ventilated area. Wear protective gloves, protective clothing, eye protection and face protection. Wash hands thoroughly after handling.
  • Waste disposal: Dispose of contents and container in accordance with local, regional, national and international regulations.
  • Reference: Refer to the Safety Data Sheet (SDS) for detailed handling and disposal information.

Complete Your RFQ

0/ 2000

why choose us

Trusted Manufacturer

With our own production facilities, we ensure consistent quality, reliable supply, and full traceability.

Rigorous Quality Assurance

Each batch undergoes strict QC, accompanied by COA, MSDS, and full compliance with international standards.

Advanced R&D Expertise

Our in-house lab drives process innovation, new product development, and tailored synthesis solutions.