

share
Phosphomolybdic Acid CAS NO 11104-88-4
Unit Price:
CAS No.:11104-88-4
Grade:Customizable
Content:Customizable
Brand:Customizable
Packaging:Customizable
Description
Phosphomolybdic Acid (CAS 11104-88-4) is a heteropoly acid of the Keggin-type phosphomolybdic acid family, commonly encountered as the hydrated form. It is a yellow crystalline solid, typically supplied as crystalline granules, and is freely soluble in water and in many polar organic solvents. Its structure is built from a central phosphate tetrahedron surrounded by molybdate octahedra, giving a polyoxometalate framework with strongly acidic protons and readily accessible molybdenum redox centers. In analytical chemistry and in oxidation-catalysis research, it serves as a reagent whose acidity and reversible molybdenum redox behavior underpin its analytical and catalytic functions.
In analytical and laboratory reagent preparation, Phosphomolybdic Acid is used as a colorimetric and staining reagent, where its reduction to intensely colored molybdenum blue species provides the basis for detection and quantification of reducing substances. The resulting reagent solutions are used in laboratory analysis, chromatography visualization, and related testing workflows.
Application
- Colorimetric analysis: In colorimetric analysis, Phosphomolybdic Acid serves as a reagent whose molybdenum centers are reduced to form intensely blue molybdenum blue species, providing the basis for spectrophotometric determination of reducing analytes such as phosphate, silicate, and ascorbic acid.
- Chromatography visualization: In thin-layer and paper chromatography, Phosphomolybdic Acid serves as a staining reagent, where its reduction on heating with organic compounds produces visible dark spots, enabling detection of lipids, steroids, and other oxidizable compounds.
- Oxidation catalysis research: In oxidation catalysis research, Phosphomolybdic Acid serves as a polyoxometalate catalyst component, where its acidic protons and redox-active molybdenum centers contribute to oxidation and acid-catalyzed reaction studies.
- Heteropoly acid chemistry research: In heteropoly acid chemistry research, Phosphomolybdic Acid serves as a model Keggin-type polyoxometalate, where its well-defined framework supports studies of acid strength, redox behavior, and counterion exchange.
- Electron microscopy staining: In electron microscopy, Phosphomolybdic Acid serves as a negative staining reagent, where its electron-dense molybdenum framework provides contrast for imaging of biological and polymeric specimens.
- Reagent preparation: In laboratory reagent preparation, Phosphomolybdic Acid serves as a starting material for preparing phosphomolybdate reagent solutions, where its solubility and acidity allow formulation of stable working reagents for analytical use.
Basic Information
| Property | Value |
|---|---|
| Product Name | Phosphomolybdic Acid |
| CAS No. | 11104-88-4 |
| Molecular Formula | UNKNOWN |
| Molecular Weight | 1825.25 g/mol (anhydrous) |
| Physical | Crystalline granules |
| Color | Yellow |
| Chemical Property | UNKNOWN |
| Customization | Content/concentration customizable per client specification |
Quality Control
The quality of Phosphomolybdic Acid is governed by its heteropoly acid composition, hydration state, and molybdenum redox behavior, which directly affect its performance as an analytical reagent and catalyst component.
| Differentiated QC focus | Structure, application impact, detection and control |
|---|---|
| Heteropoly acid identity and composition | The Keggin-type phosphomolybdic acid framework determines reagent reactivity and catalytic behavior. In colorimetric analysis and oxidation catalysis research, deviations in composition can alter reduction behavior and color development. Confirm identity by FTIR and Raman spectroscopy of the polyoxometalate framework, and set agreed specification limits on molybdenum and phosphorus content. |
| Hydration state and water content | Phosphomolybdic Acid is commonly hydrated, and water content affects effective acid strength and reagent concentration. In reagent preparation, variable hydration can shift working solution strength and colorimetric response. Set agreed limits on water content and control drying or equilibration during packaging. Test by Karl Fischer titration or loss-on-drying. |
| Acidity and free acid content | Strongly acidic protons on the heteropoly anion drive acid-catalyzed functions. In catalysis research and reagent preparation, acidity variation can affect reaction rates and reagent performance. Set agreed limits on acid content and titrate against a standardized base. |
| Molybdenum redox behavior | Reversible reduction of molybdenum centers underlies molybdenum blue formation. In colorimetric analysis, inconsistent redox behavior can cause calibration drift or weak color development. Verify reduction response against a reference standard and trend results across lots. |
| Solubility and solution clarity | Complete dissolution is required for homogeneous reagent solutions. In analytical workflows, undissolved residue or haze can cause inaccurate results. Set agreed limits on insoluble matter and inspect prepared solutions for clarity. |
| Trace metals and impurities | Residual metals or impurities from raw materials can interfere with colorimetric determinations or catalyze side reactions. In trace analysis, metal impurities can raise background signal. Qualify raw materials and set specification limits on key trace metals where the application requires. Test by ICP-OES or ICP-MS where relevant. |
Batch release, COA and traceability. Each batch is released only when it conforms to the agreed specification. The Certificate of Analysis (COA) records the actual analytical methods and results for that released batch. Batch identity and results remain traceable, with lot trending used where it supports consistency review.
Storage
- Storage conditions: Store in a cool, dry, well-ventilated area. Keep containers tightly closed when not in use.
- Secure storage: Store in a secure, designated area with access limited to authorized personnel.
- Incompatible materials: Keep away from strong reducing agents and strong bases.
- Handling precautions: Avoid breathing dust. Use only in a well-ventilated area. Wear protective gloves, protective clothing, eye protection, and face protection. Wash hands thoroughly after handling.
- Waste disposal: Dispose of contents and container in accordance with local, regional, national, and international regulations.
- Reference: Refer to the Safety Data Sheet (SDS) for detailed handling and disposal information.
Hot Related Products


Boron Trifluoride-Acetic Acid Complex CAS NO 373-61-5


Amberlyst(R) 15 CAS NO 39389-20-3


Iron Naphthenate CAS NO 1338-14-3


Triethylenediamine CAS NO 280-57-9


Bcdmh CAS NO 32718-18-6


Manganese Stearate CAS NO 3353-05-7


Hexahydro-1,3,5-Trinitro-1,3,5-Triazine CAS NO 121-82-4


Tetrabutyl Ammonium Chloride CAS NO 1112-67-0


2-Methyl-1,4-Diazabicyclo[2.2.2]Octane CAS NO 1193-66-4


Alumina CAS NO 1333-84-2


Phosphotungstic Acid CAS NO 1343-93-7


Subtilisins CAS NO 1395-21-7


Benzyltriethylammonium Hydroxide CAS NO 1836-42-6


Sodium Hypophosphite Monohydrate CAS NO 10039-56-2


12-Molybdosilicic Acid Hydrate CAS NO 11089-20-6


Copper Chromite CAS NO 11104-65-7


Cerium Aluminum Oxide Nanopowder 99 CAS NO 12014-44-7


Copper Chromite CAS NO 12018-10-9


Zinc-Copper Couple CAS NO 12019-27-1


Tetramethylammonium Nitrate CAS NO 1941-24-8
why choose us
Trusted Manufacturer
With our own production facilities, we ensure consistent quality, reliable supply, and full traceability.
Rigorous Quality Assurance
Each batch undergoes strict QC, accompanied by COA, MSDS, and full compliance with international standards.
Advanced R&D Expertise
Our in-house lab drives process innovation, new product development, and tailored synthesis solutions.






