share

tert-Butyl Peroxyisobutyrate CAS NO 109-13-7


Unit Price:

CAS No.:109-13-7

Grade:Customizable

Content:Customizable

Brand:Customizable

Packaging:Customizable

Description

tert-Butyl Peroxyisobutyrate (CAS 109-13-7) is a tert-butyl peroxyester of isobutyric acid, in which a peroxyester linkage connects a tert-butoxy group to an isobutyryl group. It is a liquid and is described as colorless. As an organic peroxide, its peroxyester bond undergoes thermally induced homolysis, generating tert-butoxy and isobutyryloxy radicals that can initiate radical chain reactions. In radical polymerization and resin processing, it serves as a radical initiator for the initiation of vinyl monomer polymerization and the curing or crosslinking of unsaturated resin systems.

In radical polymerization and resin curing processes, tert-Butyl Peroxyisobutyrate serves as a thermally activated radical source during batch and continuous polymerization, where its decomposition generates radicals that start and sustain chain growth. The resulting polymers and cured resin materials are used in industrial coatings, adhesives, molded parts, and composite fabrication for structural and protective functions.

Application

  • Radical polymerization initiation: In radical polymerization of vinyl monomers, tert-Butyl Peroxyisobutyrate serves as a thermal radical initiator, where its peroxyester decomposition generates radicals that initiate chain growth. The resulting polymers are used in industrial coatings, adhesives, and molded plastic articles.
  • Unsaturated resin curing: In unsaturated polyester and vinyl ester resin systems, tert-Butyl Peroxyisobutyrate serves as a curing initiator, where its thermal decomposition provides radicals that drive crosslinking. The resulting cured resins are used in composite parts, gel coats, and industrial laminates.
  • Crosslinking of polymers: In polymer crosslinking processes, tert-Butyl Peroxyisobutyrate serves as a radical source, where its decomposition abstracts hydrogen or adds to unsaturated sites to form crosslinks. The resulting crosslinked materials are used in wire and cable insulation, foams, and molded rubber components.
  • Graft polymerization: In graft polymerization, tert-Butyl Peroxyisobutyrate serves as an initiator for radical grafting onto polymer backbones, where its decomposition radicals create grafting sites. The resulting graft-modified polymers are used in compatibilizers and specialty polymer compounds.
  • Polymer modification: In polymer modification processes, tert-Butyl Peroxyisobutyrate serves as a radical generator for controlled chain modification, where its decomposition contributes to molecular weight and branching adjustment. The resulting modified polymers are used in industrial formulation and processing.

Basic Information

Property Value
Product Name tert-Butyl Peroxyisobutyrate
CAS No. 109-13-7
Molecular Formula UNKNOWN
Molecular Weight 160.21 g/mol
Physical Liquid
Color Colorless
Chemical Property UNKNOWN
Customization Content/concentration customizable per client specification

Quality Control

The quality of tert-Butyl Peroxyisobutyrate is governed by its peroxyester content and thermal decomposition behavior, which directly affect initiation efficiency and reproducibility in polymerization and resin curing. Because the active oxygen content determines the radical yield, its control is central to consistent performance.

Differentiated QC focus Structure, application impact, detection and control
Active oxygen and peroxyester content The peroxyester group is the source of radicals; its content determines the effective initiator dose. In polymerization and resin curing, low active oxygen can cause incomplete conversion or under-cure, while excess can cause premature gelation or runaway reaction. Control by assay of active oxygen or peroxyester content against an agreed specification, with raw-material qualification and lot trending.
Thermal decomposition behavior The decomposition temperature and half-life govern the temperature window in which radicals are generated. In batch and continuous polymerization, a shifted decomposition profile can cause inconsistent initiation, scorch, or incomplete cure. Control by measuring decomposition kinetics or half-life in a representative solvent and comparing against an agreed reference.
Appearance and clarity The product is described as a colorless liquid; color or haze can indicate decomposition, contamination, or moisture ingress. In clear resin and coating applications, color or turbidity can affect product appearance. Control by visual comparison against a standard and by checking containers for contamination.
Moisture and volatile content Water or volatiles can affect peroxide stability and initiator performance. In resin curing, moisture can cause bubbles, voids, or inconsistent cure. Control by Karl Fischer titration or loss-on-drying where appropriate, with moisture-exclusion during packaging and storage.
Storage stability and self-accelerating decomposition Organic peroxides can decompose exothermically and, under confinement or elevated temperature, may undergo self-accelerating decomposition. In storage and handling, inadequate temperature control can cause activity loss or hazardous decomposition. Control by defined storage temperature limits, stability monitoring, and inventory rotation.

Batch release, COA and traceability. Each batch is released only when it conforms to the agreed specification. The Certificate of Analysis (COA) records the actual analytical methods and results for that released batch. Batch identity and results remain traceable, with lot trending used where it supports consistency review.

Storage

  • Storage conditions: Store in a cool, dry, well-ventilated area away from heat, sparks, and direct sunlight. Keep containers tightly closed when not in use.
  • Secure storage: Store in a secure, designated area with access limited to authorized personnel.
  • Incompatible materials: Keep away from strong acids, strong bases, reducing agents, and combustible materials.
  • Handling precautions: Avoid breathing vapors or mist. Use only in a well-ventilated area. Wear protective gloves, protective clothing, eye protection, and face protection. Wash hands thoroughly after handling.
  • Waste disposal: Dispose of contents and container in accordance with local, regional, national, and international regulations.
  • Reference: Refer to the Safety Data Sheet (SDS) for detailed handling and disposal information.

Complete Your RFQ

0/ 2000

why choose us

Trusted Manufacturer

With our own production facilities, we ensure consistent quality, reliable supply, and full traceability.

Rigorous Quality Assurance

Each batch undergoes strict QC, accompanied by COA, MSDS, and full compliance with international standards.

Advanced R&D Expertise