AATCC TM146 Disperse Dye Test: Filtration Time and Filter Residue
For incoming disperse dyes, an AATCC TM146 result supports dispersibility acceptance when both filtration time and filter residue meet the grade’s limits and the approved reference lot is in control. If filtration is slow but the residue rating passes, hold the lot and check the filtration setup and test conditions. If only the residue fails, verify the paper and rating procedure before repeating the test. When two valid results fall on opposite sides of a limit, retain both and use the agreed retest rule. These decisions apply to formulated disperse dyes for polyester exhaust dyeing under the specified aqueous test conditions.
What counts as a comparable AATCC TM146 result?
The public scope of AATCC TM146-2011(2022)e describes three procedures according to intended dye application. A defined amount of dye is diluted and heated, then passed through specified filter papers. Report the procedure used as well as the filtration time and the filter residue outcome. A result reported as “TM146: Pass” has limited value in a disputed release if the procedure, test conditions or agreed limits are missing.
Use the controlled method and purchase specification to confirm dye mass or concentration, water, mixing and heating conditions, filter paper and setup, and timing endpoint. For residue, use the agreed visual assessment and report the rating or observation by filter if the procedure calls for it. Check the rating direction if laboratories transcribe the photographic reference to a numerical result. An internal mass-of-residue test or an alternative paper may provide useful diagnostic evidence. Results from a modified procedure need their own agreed acceptance basis.
How to read filtration time and filter residue together
Commercial disperse dyes for polyester contain sparingly water-soluble colorants supplied as formulations designed to disperse in the bath. In TM146, filtration time reflects how the prepared dispersion passes through the specified setup. The filter deposit shows what was retained and how it appears under the agreed rating procedure. If the endpoints disagree, inspect the filter setup first. As a working hypothesis, a deposit that restricts the flow path could slow filtration even when its appearance is within the allowed residue rating. Visible retained material can also trigger a residue failure without a time failure. Neither result identifies the material on the filter or measures the particle-size distribution.
| Observation against the agreed limits | What to check | Disposition |
|---|---|---|
| Time and residue both meet the limits, and the reference is in control. | Verify lot identity, selected procedure and complete test record. | Accept the dispersibility result for the intended grade. |
| Time is long and residue meets its limit. | Check filter seating, conditioning, test temperature and timing. Repeat with fresh preparations of the lot and the reference. | Hold the lot while confirming the time result. |
| Time meets its limit and residue fails. | Check the correct rating scale, lighting and paper, then repeat the preparation with an independent residue assessment if needed. | Hold the lot pending the residue decision. |
| Both endpoints fail and the reference is in control. | Confirm a fresh preparation and check the original sample record. | Hold the lot and apply the agreed nonconformance procedure if the failure is confirmed. |
| Both the sample and reference shift in the same run. | Check shared water, heating, paper and filtration setup. Establish a valid reference response before retesting. | Investigate the test system before assigning a lot disposition. |
If two valid preparations fall on opposite sides of the filtration-time limit while both residue ratings pass, keep both time results. Apply the retest rule already agreed for the grade. If it does not resolve the conflicting results, keep the dispersibility decision on hold. Use a common split and compare the recorded filtration conditions before either lab changes the lot status. Eurachem guidance on decision rules and measurement uncertainty
What to record when a TM146 result is disputed
Take a representative incoming sample under the agreed sampling plan and record the packages sampled. Retain a traceable split for supplier comparison. Confirm that the reference lot’s age and storage still support its use as a control. When a result is near the limit or differs from the supplier’s result, request both labs’ records before repeating the test. Record the procedure and edition, filter identification, filtration time and its endpoint, residue rating and scale, plus the reference lot’s results for both measures. Prepare a fresh dispersion from the retained sample and run the reference alongside it.
If the laboratories still disagree after method alignment, exchange portions of a common sample, the timed results and images of the filters with their ratings. Use consistent lighting and image capture so the photographs support comparison. A confirmed failure in either required endpoint is a dispersibility nonconformance. Document the lot disposition through the agreed quality process. A valid TM146 pass supports the filter-test requirement. Release for the dyehouse recipe still depends on the separate shade, strength and any process-specific criteria.
The ChemicalCell Disperse Dyes directory identifies the material family. Use the exact formulation and grade specification when setting up the comparison.