Inorganic Powder Raw Materials: Defining D10, D50, D90 and Measurement Conditions in Acceptance Specifications
D10, D50 and D90 become useful acceptance criteria only when the specification defines their distribution basis, measurement method and sample preparation. For volume-based laser diffraction, Dv10, Dv50 and Dv90 are the diameters below which 10%, 50% and 90% of the reported particle volume lie. Dv50 is a median; Dv90 is not a maximum size. The specification must also identify the dispersion state being evaluated. Otherwise, supplier and receiving laboratories can report different results because they prepared or analyzed the powder differently, leaving the apparent batch difference unresolved.
This article addresses QA/QC personnel defining incoming acceptance specifications for industrial inorganic powders, with oxide materials such as alumina and zirconia as representative examples. Its focus is volume-based laser diffraction. Limits and preparation conditions must be established for the particular material and grade; they cannot be transferred automatically between oxide families.
Define What Each Percentile Controls
Use explicit notation and units in the specification. “D50: conforms” or “average particle size” leaves the measured quantity unclear.
| Parameter | Meaning on a volume basis | What it does not establish |
| Dv10 | Diameter below which 10% of reported particle volume lies | The smallest particle or the number of fine particles |
| Dv50 | Diameter below which 50% of reported particle volume lies | An arithmetic mean or the complete distribution |
| Dv90 | Diameter below which 90% of reported particle volume lies | A maximum particle size or absence of oversized particles |
A volume percentile and a number percentile answer different questions. Do not compare them as equivalent values simply because both reports use “D50.”
HORIBA’s guidance on particle-size specifications recommends retaining the primary distribution basis of the measurement technique and cautions against converting laser-diffraction volume results to a number basis. It also explains why one central value cannot describe distribution width.
Select the direction of each limit deliberately. A Dv10 minimum, a Dv10 maximum and a permitted Dv10 interval impose different controls. The same applies to the other percentiles. Establish which control is supported by qualified material and process evidence before assigning a numerical limit.
Decide Which Dispersion State the Specification Represents
For an inorganic powder, the acceptance method must identify whether it evaluates a reproducibly dispersed population or deliberately preserves some agglomeration.
Malvern Panalytical’s wet-dispersion guidance distinguishes measuring the extent of agglomeration from measuring a more fully dispersed population. It also identifies representative sampling, a stable dispersion state and appropriate measurement conditions as separate requirements for reproducibility.
This distinction changes the release question.
If the agreed method includes a defined deagglomeration step, a result obtained without that step may describe a different population. Conversely, intensive preparation may be inappropriate where the specified property concerns granules or agglomerates intended to remain intact.
For a surface-treated oxide grade, include the treatment status in the material identity and assess whether the chosen preparation remains suitable. Do not assume that a method developed for an untreated powder transfers unchanged.
Define the analytical endpoint before optimizing preparation. “Use enough energy to obtain the smallest result” is not an adequate endpoint.
Establish Dispersion Conditions without Altering the Material
Wet and dry methods need separate development. Neither is automatically the reference method for every inorganic powder.
Wet dispersion
Choose a liquid that wets the powder without dissolving it or otherwise changing the population being evaluated. Record the liquid and any dispersing additive, together with the preparation sequence.
A useful development sequence is to observe repeated results during circulation, assess the response to controlled sonication, and then check stability after sonication stops. Malvern Panalytical describes this approach in its wet-dispersion method-development guidance.
A decreasing percentile during preparation is a measurement observation. It does not, by itself, identify whether agglomerates separated, particles fractured or another change occurred. Where that distinction affects acceptance, obtain corroborating evidence before fixing the preparation conditions.
Dry dispersion
Evaluate dispersion pressure together with the feed conditions. Increasing pressure can separate agglomerates, but it can also cause particle attrition; these processes may overlap. Malvern Panalytical’s dry-dispersion guidance therefore uses pressure-response studies and comparison with a suitable dispersed reference to investigate the operating condition.
A stable result across a selected pressure range supports method robustness under those conditions. It does not independently prove that every measured object is a primary particle.
Once the intended state is established, fix the preparation conditions in the controlled procedure. Changing them to obtain a passing result changes the analytical basis of acceptance.
Make the Measurement Conditions Part of the Specification
The numerical limits can remain concise if they reference a complete, controlled method. The certificate of analysis should identify that method and its revision.
| Method element | What to define | Acceptance purpose |
| Material identity | Grade, treatment status and any agreed conditioning | Establishes which powder the method covers |
| Sampling and subdivision | Lot-sampling plan, laboratory subdivision and test portion | Connects the measured portion to the material being accepted |
| Measurement system | Instrument, dispersion accessory and controlled software settings | Makes the analytical configuration traceable |
| Distribution basis | Volume basis, percentile notation and units | Prevents comparison of different reported quantities |
| Wet preparation | Liquid, additives, mixing, circulation and sonication conditions | Defines the dispersed state examined |
| Dry preparation | Dispersion configuration, pressure and feed conditions | Defines the mechanical treatment applied |
| Analysis | Optical model and applicable optical properties | Defines how scattering data become a size distribution |
| Acquisition and reporting | Concentration range, acquisition conditions, independent preparations and calculation rules | Defines how results are generated and combined |
Malvern Panalytical’s 2025 reporting guidance identifies dispersant, optical model, optical properties, dispersion conditions and optical concentration as information needed to reproduce laser-diffraction results. For Mie analysis, it specifies particle refractive index, particle absorption index and dispersant refractive index.
These settings require a technical basis. Do not select optical properties solely because they move a result inside the specification.
Establish the appropriate optical concentration range during method development. Malvern Panalytical notes that suitable obscuration conditions depend on particle size and differ between wet and dry measurement. A universal obscuration target is therefore unsuitable for this article’s broad material scope.
Keep Percentile Limits Separate from Oversize Requirements
Dv90 controls a point on the cumulative distribution. It leaves the upper part of the distribution incompletely described.
For example, a hypothetical result of Dv90 = 20 µm means that 90% of the reported particle volume lies below 20 µm. It does not establish that every particle is below that diameter. This is a definition example, not a recommended oxide specification.
Where acceptance depends on material above a particular size, define a separate requirement for that fraction and demonstrate that the selected method can measure it suitably. If the concern is rare oversized objects, assess whether an additional examination is needed.
Do not substitute D100 automatically. HORIBA cautions that extreme endpoints such as D100 are particularly sensitive to measurement disturbances.
Retain the full cumulative and differential distributions during qualification and investigations. Three percentiles summarize selected positions; they do not uniquely define every feature of the distribution.
Establish Precision before Finalizing Release Limits
Distinguish repeat scans of one preparation from independent preparations. Repeated scans examine measurement stability within that preparation. Independent preparation studies also test the subdivision and preparation steps being repeated.
For supplier-to-receiver transfer, use representative split material and the agreed method. Compare each controlled percentile, the full distributions and the relevant preparation records.
Set the required precision and interlaboratory agreement from the method’s demonstrated capability and the intended decision. Avoid importing a generic percentage without checking its source, applicability and meaning.
The controlled specification should state how independent results are combined, how rounding is applied and how borderline results are handled. Agree these rules before a disputed lot arrives.
A method reference or standard number alone cannot supply the material-specific preparation or establish that the method can reliably distinguish the proposed acceptance boundaries.
Resolve a Disputed Result on the Agreed Analytical Basis
When a receiving result exceeds a limit, first establish whether the agreed method was followed.
A different distribution basis, omitted preparation step or changed optical model calls comparability into question. It does not establish that the lot is acceptable. Likewise, obtaining a passing result after changing dispersion conditions does not resolve the original result without an investigation.
Use fresh representative portions to examine preparation reproducibility where needed. Review the distribution curves alongside the reported percentiles. Follow the established nonconformance procedure when a valid result fails the agreed criterion.
ChemicalCell’s Oxides and Peroxides category provides a starting point for identifying oxide materials. A grade-specific particle-size specification still requires its own method and acceptance evidence.
Before approving the specification, confirm that both laboratories can reproduce the intended dispersion state and interpret the same percentile limits consistently. Release then rests on a defined measurement of the powder, with a documented response when the evidence is incomplete or outside the agreed limits.