share

Butanedioic Acid, Hydroxy-, Sodium Salt, (2S)- CAS NO 63441-17-8


Unit Price:

CAS No.:63441-17-8

Grade:Customizable

Content:Customizable

Brand:Customizable

Packaging:Customizable

Description

Butanedioic Acid, Hydroxy-, Sodium Salt, (2S)- (CAS 63441-17-8) is the monosodium salt of (2S)-hydroxybutanedioic acid, the naturally occurring L-enantiomer of malic acid. It is recorded as a fine, off-white powder. The molecule carries one free carboxylic acid group and one carboxylate group together with a secondary hydroxyl group on the C2 carbon, so it combines acidic and chelating functionality in a single small molecule. In aqueous systems it participates in acid–base equilibria and can act as a pH-adjusting and buffering component, and its hydroxyl–carboxylate arrangement allows it to coordinate polyvalent metal ions. In food and general industrial formulation, it serves as an acidity regulator and pH-control agent for adjusting and stabilizing the acid profile of aqueous products.

In aqueous formulation and liquid product manufacturing, Butanedioic Acid, Hydroxy-, Sodium Salt, (2S)- is dosed as a water-soluble acidulant and buffer component during batch preparation, where its free carboxyl and carboxylate groups contribute to pH adjustment and buffering capacity. The resulting adjusted aqueous systems are used in food and general industrial processing for controlling acidity and stabilizing pH during storage.

Application

  • Acidity regulation in food systems: In food and beverage formulation, Butanedioic Acid, Hydroxy-, Sodium Salt, (2S)- serves as an acidity regulator, where its free carboxylic acid and carboxylate groups contribute to adjusting and stabilizing the acid profile. The resulting products are used in food and beverage manufacture for consistent tartness and pH control.
  • pH adjustment and buffering: In aqueous processing, Butanedioic Acid, Hydroxy-, Sodium Salt, (2S)- serves as a pH-adjusting and buffering agent, where its acid–base equilibrium contributes to holding pH within a target window. The resulting solutions are used in general industrial and food processing streams where pH stability is required.
  • Metal-ion chelation: In aqueous formulation, Butanedioic Acid, Hydroxy-, Sodium Salt, (2S)- serves as a chelating component, where its hydroxyl and carboxylate groups contribute to binding polyvalent metal ions. The resulting formulations are used in general industrial processing to limit metal-catalyzed degradation and precipitation.
  • Flavor and acid-profile formulation: In flavor and acidulant formulation, Butanedioic Acid, Hydroxy-, Sodium Salt, (2S)- serves as a mild acidulant, where its smooth acidity contributes to rounding and balancing flavor profiles. The resulting blends are used in food and beverage applications.
  • Buffer preparation for analytical work: In analytical and laboratory work, Butanedioic Acid, Hydroxy-, Sodium Salt, (2S)- may be evaluated as a buffer component, where its acid–base behavior supports preparation of pH-controlled aqueous media.

Basic Information

Property Value
Product Name Butanedioic Acid, Hydroxy-, Sodium Salt, (2S)-
CAS No. 63441-17-8
Molecular Formula UNKNOWN
Molecular Weight 156.07 g/mol
Physical fine powder
Color off-white
Chemical Property UNKNOWN
Customization Content/concentration customizable per client specification

Quality Control

The quality of Butanedioic Acid, Hydroxy-, Sodium Salt, (2S)- is governed by its identity as the (2S)-enantiomer of the monosodium salt, its acid–base behavior, and its water content, all of which affect pH adjustment and buffering performance in aqueous systems.

Differentiated QC focus Structure, application impact, detection and control
Identity and stereochemistry The product is the (2S)-enantiomer of the monosodium salt of hydroxybutanedioic acid; the L-configuration and the mono/di-salt ratio determine its acidity and buffering behavior. In food and industrial pH control, an incorrect enantiomer or salt form shifts the acid profile and buffering capacity. Confirm identity and configuration by optical rotation, chiral HPLC, or NMR, and control the salt form by titration of free acid and total carboxylate.
Assay and salt-form ratio The balance between the free acid and carboxylate groups sets the effective acidity delivered per unit mass. In acidity regulation, a shifted mono/di-salt ratio changes the amount needed to reach a target pH. Determine assay by acid–base titration or ion chromatography, and set an agreed specification range for the salt-form ratio.
Water content The material is hygroscopic, so absorbed water dilutes the active content and shifts the effective acid concentration. In buffering and pH adjustment, variable water content causes inconsistent dosing and pH response. Control moisture by Karl Fischer titration, set a water specification, and use moisture-barrier packaging.
pH of aqueous solution The pH of a prepared solution reflects the salt form and residual acidity and directly affects the target system. In food and industrial processing, an out-of-range solution pH changes the acid profile of the finished product. Measure the pH of a defined aqueous solution against an agreed range as a routine release check.
Appearance and particulate quality The product is recorded as a fine, off-white powder; discoloration or coarse agglomerates can indicate degradation or moisture uptake. In food and formulation use, color and particle variation affect dissolution and appearance. Inspect visually against a standard and control particle size where dissolution rate matters.
Trace metals and impurities Residual metal ions and process impurities can interfere with chelation behavior and with metal-sensitive formulations. In chelation and buffering applications, metal impurities reduce effective chelating capacity. Qualify raw materials and set limits for relevant metals by ICP-OES where the application requires.

Batch release, COA and traceability. Each batch is released only when it conforms to the agreed specification. The Certificate of Analysis (COA) records the actual analytical methods and results for that released batch. Batch identity and results remain traceable, with lot trending used where it supports consistency review.

Storage

  • Storage conditions: Store in a cool, dry, well-ventilated area. Keep containers tightly closed when not in use to limit moisture uptake.
  • Secure storage: Store in a secure, designated area with access limited to authorized personnel.
  • Incompatible materials: Keep away from strong oxidizers.
  • Handling precautions: Avoid breathing dust. Use only in a well-ventilated area. Wear protective gloves, protective clothing, eye protection, and face protection. Wash hands thoroughly after handling.
  • Waste disposal: Dispose of contents and container in accordance with local, regional, national, and international regulations.
  • Reference: Refer to the Safety Data Sheet (SDS) for detailed handling and disposal information.

Complete Your RFQ

0/ 2000

why choose us

Trusted Manufacturer

With our own production facilities, we ensure consistent quality, reliable supply, and full traceability.

Rigorous Quality Assurance

Each batch undergoes strict QC, accompanied by COA, MSDS, and full compliance with international standards.

Advanced R&D Expertise

Our in-house lab drives process innovation, new product development, and tailored synthesis solutions.