share

Ammonium Hydrogen Malate CAS NO 5972-71-4


Unit Price:

CAS No.:5972-71-4

Grade:Customizable

Content:Customizable

Brand:Customizable

Packaging:Customizable

Description

Ammonium Hydrogen Malate (CAS 5972-71-4) is the monoammonium acid salt of malic acid, in which one of the two carboxylic acid groups of malic acid is neutralized by ammonia while the second carboxyl group remains in its free acid form. It is recorded as a white, crystalline granular solid. As an acid salt, it carries both an ammonium cation and a residual carboxylic acid function, so its behavior in aqueous systems depends on the balance between the ammonium group and the free carboxyl group. In aqueous formulation work it serves as an acidic salt component for pH adjustment and buffer preparation, where the partial neutralization of malic acid gives a milder acidity than the free diacid.

In aqueous processing and formulation, Ammonium Hydrogen Malate is handled as a water-soluble acid salt that is introduced at the pH-adjustment or buffering stage of a batch. Its combination of an ammonium counter-ion and a residual carboxylic acid group allows formulators to shift and hold pH in the mildly acidic range while contributing a malate anion to the system. The resulting adjusted or buffered aqueous media are used in general industrial and laboratory processing where controlled acidity is required.

Application

  • pH adjustment in aqueous systems: In aqueous formulation and processing, Ammonium Hydrogen Malate serves as an acidic salt for lowering or stabilizing pH, where its residual free carboxyl group contributes acidity while the ammonium group provides the counter-ion. The resulting adjusted aqueous medium is used where a mildly acidic pH must be established and maintained.
  • Buffer preparation: In buffer preparation, Ammonium Hydrogen Malate serves as an acid component of a malate-based buffer pair, where the partial neutralization of malic acid provides a conjugate acid/base relationship with its more fully neutralized salt forms. The resulting buffer solutions are used in laboratory and industrial aqueous systems requiring controlled pH.
  • Acidulant formulation: In acidulant formulation, Ammonium Hydrogen Malate serves as a mild acidulant, where its acid salt character contributes a moderated acidity compared with the free diacid. The resulting formulated aqueous products are used where a less aggressive acid profile is desired.
  • Laboratory reagent use: In laboratory work, Ammonium Hydrogen Malate serves as a malate and ammonium source for solution preparation and pH studies, where its defined acid salt composition allows controlled introduction of both ions. The resulting prepared solutions are used in general analytical and experimental aqueous work.
  • Metal-ion and solution studies: In aqueous solution studies, Ammonium Hydrogen Malate may be evaluated as a malate ligand source, where the carboxylate and hydroxyl functions of the malate anion can interact with dissolved metal ions. This is an evaluation context rather than a confirmed commercial application.

Basic Information

Property Value
Product Name Ammonium Hydrogen Malate
CAS No. 5972-71-4
Molecular Formula UNKNOWN
Molecular Weight 151.12 g/mol
Physical Crystalline granules
Color White
Chemical Property UNKNOWN
Customization Content/concentration customizable per client specification

Quality Control

The quality of Ammonium Hydrogen Malate is governed by its identity as a monoammonium acid salt of malic acid, so the ratio of ammonium to malate and the residual free acidity are the properties that most directly affect its behavior in pH adjustment and buffer preparation.

Differentiated QC focus Structure, application impact, detection and control
Identity and salt stoichiometry The product is the monoammonium salt of malic acid, and the degree of neutralization determines how much free carboxyl acidity remains. In pH adjustment and buffer preparation, a shift toward the diammonium salt reduces acidity and changes buffering behavior. Confirm identity and the ammonium-to-malate ratio against an agreed specification, and trend the ratio across lots.
Acidity and pH behavior The residual carboxylic acid group sets the acidity contributed to aqueous systems. In buffered or acidified media, variation in free acidity shifts the achieved pH and the buffer capacity. Set an agreed acidity or pH specification for a defined solution concentration, and check it on each lot.
Water content The material is recorded as hygroscopic, so absorbed water changes the effective acid concentration on a mass basis. In pH adjustment, moisture variation shifts the amount needed to reach a target pH. Control moisture during packaging and storage, set a water content limit, and determine it by Karl Fischer titration or loss on drying.
Appearance and particulate form The product is recorded as white crystalline granules, and color or form changes can indicate contamination or degradation. In solution preparation, off-color or caked material can slow dissolution and introduce undissolved residue. Compare lots visually against an agreed standard and inspect for caking or discoloration.
Water-insoluble matter Insoluble residue can arise from raw materials or handling. In buffer and solution preparation, insoluble matter causes turbidity and can interfere with optical or analytical measurements. Set a limit on insoluble matter and check it by filtration of a defined solution followed by gravimetric determination.

Batch release, COA and traceability. Each batch is released only when it conforms to the agreed specification. The Certificate of Analysis (COA) records the actual analytical methods and results for that released batch. Batch identity and results remain traceable, with lot trending used where it supports consistency review.

Storage

  • Storage conditions: Store in a cool, dry, well-ventilated area. Keep containers tightly closed when not in use to limit pickup of atmospheric moisture.
  • Secure storage: Store in a secure, designated area with access limited to authorized personnel.
  • Incompatible materials: Keep away from strong oxidizing agents and strong bases.
  • Handling precautions: Avoid breathing dust. Use only in a well-ventilated area. Wear protective gloves, protective clothing, eye protection, and face protection. Wash hands thoroughly after handling.
  • Waste disposal: Dispose of contents and container in accordance with local, regional, national, and international regulations.
  • Reference: Refer to the Safety Data Sheet (SDS) for detailed handling and disposal information.

Complete Your RFQ

0/ 2000

why choose us

Trusted Manufacturer

With our own production facilities, we ensure consistent quality, reliable supply, and full traceability.

Rigorous Quality Assurance

Each batch undergoes strict QC, accompanied by COA, MSDS, and full compliance with international standards.

Advanced R&D Expertise

Our in-house lab drives process innovation, new product development, and tailored synthesis solutions.