Description

1-Dodecene, Polymer With 1-Octene, Hydrogenated (CAS 163149-29-9) is a hydrogenated copolymer derived from 1-dodecene and 1-octene, in which the unsaturated olefin units of the polymer backbone have been converted to saturated hydrocarbon structures. It is a viscous liquid and is colorless. As a fully saturated hydrocarbon copolymer, it is composed only of carbon and hydrogen and is expected to show low polarity, low reactivity toward oxidation and good compatibility with hydrocarbon-based materials. In hydrocarbon fluid and polymer-related formulation, it serves as a saturated hydrocarbon copolymer component for applications where low polarity and stability against oxidation are relevant.

In hydrocarbon fluid formulation and polymer-related material preparation, 1-Dodecene, Polymer With 1-Octene, Hydrogenated serves as a saturated hydrocarbon copolymer component during batch blending and repeated manufacturing. The resulting hydrocarbon-based fluids and material formulations are used in industrial lubrication and polymer processing contexts for functions that rely on low-polarity, oxidation-resistant hydrocarbon behavior.

Application

  • Lubricant base fluid component: In lubricant formulation, 1-Dodecene, Polymer With 1-Octene, Hydrogenated serves as a saturated hydrocarbon copolymer component, where its fully hydrogenated backbone contributes to low polarity and resistance to oxidative change. The resulting lubricant formulations are used in industrial lubrication contexts.
  • Hydrocarbon fluid formulation: In hydrocarbon fluid formulation, 1-Dodecene, Polymer With 1-Octene, Hydrogenated serves as a hydrocarbon copolymer component, where its saturated structure contributes to compatibility with hydrocarbon-based media. The resulting fluids are used in industrial material and equipment contexts.
  • Polymer processing aid: In polymer processing, 1-Dodecene, Polymer With 1-Octene, Hydrogenated serves as a hydrocarbon copolymer component, where its saturated hydrocarbon structure contributes to compatibility with polyolefin-type materials. The resulting compounds are used in industrial polymer processing.
  • Hydrocarbon-based material formulation: In hydrocarbon-based material formulation, 1-Dodecene, Polymer With 1-Octene, Hydrogenated serves as a saturated hydrocarbon copolymer component, where its carbon-hydrogen-only composition contributes to low-polarity material behavior. The resulting materials are used in industrial formulation contexts.

Basic Information

Property Value
Product Name 1-Dodecene, Polymer With 1-Octene, Hydrogenated
CAS No. 163149-29-9
Molecular Formula UNKNOWN
Molecular Weight UNKNOWN
Physical Viscous liquid
Color Colorless
Chemical Property UNKNOWN
Customization Content/concentration customizable per client specification

Quality Control

The quality of 1-Dodecene, Polymer With 1-Octene, Hydrogenated is governed by its identity as a fully saturated hydrocarbon copolymer of 1-dodecene and 1-octene, which determines its low polarity, oxidation stability and compatibility behavior in hydrocarbon fluid and polymer-related applications.

Differentiated QC focus Structure, application impact, detection and control
Copolymer identity and composition The product is a copolymer of 1-dodecene and 1-octene with a hydrogenated backbone. In hydrocarbon fluid and polymer-related formulation, the comonomer ratio and chain structure affect polarity, compatibility and flow behavior. Confirm identity and composition against an agreed specification, and trend composition against application-relevant performance. Test by FTIR and 1H NMR for structural confirmation, with GPC for molecular-weight distribution where a suitable solvent and calibration are available.
Degree of hydrogenation and unsaturation Residual unsaturation after hydrogenation affects oxidation stability and color behavior. In lubricant and hydrocarbon fluid applications, incomplete hydrogenation can reduce oxidative stability and promote color development. Set an agreed limit on residual unsaturation and trend it against stability results. Test by iodine value titration or 1H NMR integration of residual olefinic protons.
Viscosity and molecular-weight distribution Chain length and distribution determine flow and processing behavior. In lubricant base fluid and polymer processing applications, viscosity and molecular-weight distribution affect pumping, blending and flow. Use agreed viscosity ranges and lot comparison by GPC. Test by rotational viscometry or rheology for viscosity and by SEC/GPC for molecular-weight distribution.
Volatile matter Volatiles can arise from residual low-molecular-weight fractions or moisture. In lubricant and hydrocarbon fluid applications, volatiles can affect flash behavior, foaming and consistency. Set an agreed limit on volatile content and check lots before blending. Test by oven volatilization or headspace GC where appropriate.
Color and clarity The product is described as colorless; color development can indicate oxidation or contamination. In clear hydrocarbon fluids, color or haze affects appearance and light transmission. Set agreed color limits and protect from light and heat during storage. Test by visual comparison against a standard or colorimetry.

Batch release, COA and traceability. Each batch is released only when it conforms to the agreed specification. The Certificate of Analysis (COA) records the actual analytical methods and results for that released batch. Batch identity and results remain traceable, with lot trending used where it supports consistency review.

Storage

  • Storage conditions: Store in a cool, dry, well-ventilated area. Keep containers tightly closed when not in use.
  • Secure storage: Store in a secure, designated area with access limited to authorized personnel.
  • Incompatible materials: Keep away from strong oxidizers.
  • Handling precautions: Avoid breathing vapors or mist. Use only in a well-ventilated area. Wear protective gloves, protective clothing, eye protection, and face protection. Wash hands thoroughly after handling.
  • Waste disposal: Dispose of contents and container in accordance with local, regional, national, and international regulations.
  • Reference: Refer to the Safety Data Sheet (SDS) for detailed handling and disposal information.

Complete Your RFQ

0/ 2000

why choose us

Trusted Manufacturer

With our own production facilities, we ensure consistent quality, reliable supply, and full traceability.

Rigorous Quality Assurance

Each batch undergoes strict QC, accompanied by COA, MSDS, and full compliance with international standards.

Advanced R&D Expertise

Our in-house lab drives process innovation, new product development, and tailored synthesis solutions.