share

2-Propenoic Acid, Methyl Ester, Polymer With Diethenylbenzene, Ethenylethylbenzene And 1,7-Octadiene, Hydrolyzed CAS NO 114060-62-7


Unit Price:

CAS No.:114060-62-7

Grade:Customizable

Content:Customizable

Brand:Customizable

Packaging:Customizable

Description

2-Propenoic Acid, Methyl Ester, Polymer With Diethenylbenzene, Ethenylethylbenzene And 1,7-Octadiene, Hydrolyzed (CAS 114060-62-7) is a crosslinked hydrolyzed poly(methyl acrylate) polymer prepared from methyl acrylate with diethenylbenzene, ethenylethylbenzene and 1,7-octadiene as comonomers. It is supplied as beads or particles. The polymer backbone carries carboxylic acid and carboxylate functionality generated by hydrolysis of the methyl ester groups, and the diethenylbenzene-derived crosslinks give the material a rigid, insoluble network structure. In ion exchange, adsorption and chromatographic media applications, it serves as a crosslinked functional polymer base whose carboxylic acid groups provide cation exchange capacity and whose network structure supports fixed-bed and column operation.

In water processing, separation and purification media manufacturing, this hydrolyzed crosslinked acrylate polymer serves as a functional polymer base during bead production and repeated manufacturing of ion exchange and adsorbent media. The resulting media are used in industrial water processing, demineralization and chromatographic separation for ion removal, adsorption and fluid processing functions.

Application

  • Weak-acid cation exchange media: In water processing and demineralization, 2-Propenoic Acid, Methyl Ester, Polymer With Diethenylbenzene, Ethenylethylbenzene And 1,7-Octadiene, Hydrolyzed serves as a weak-acid cation exchange resin base, where its carboxylic acid groups contribute to cation uptake and regeneration. The resulting resin is used in industrial water processing for hardness reduction and demineralization.
  • Chromatographic separation support: In chromatographic separation, this crosslinked hydrolyzed acrylate polymer serves as a stationary phase support, where its crosslinked network and carboxylic acid functionality contribute to selective retention of cationic species. The resulting media are used in laboratory and process-scale separation of ionic compounds.
  • Adsorbent media: In adsorption processes, the polymer serves as a crosslinked adsorbent base, where its porous bead structure contributes to uptake of dissolved species. The resulting media are used in industrial purification and fluid processing.
  • Catalyst support: In catalyst support applications, this functional polymer serves as a crosslinked carrier, where its carboxylic acid groups provide sites for immobilization of catalytic species. The resulting supported systems are used in process chemistry and material conversion.
  • Polymer bead formulation research: In polymer bead formulation research, this hydrolyzed crosslinked acrylate may be evaluated as a model weak-acid functional bead, where its crosslink density and carboxylic acid content support studies of swelling and exchange behavior. This is a research evaluation context.

Basic Information

Property Value
Product Name 2-Propenoic Acid, Methyl Ester, Polymer With Diethenylbenzene, Ethenylethylbenzene And 1,7-Octadiene, Hydrolyzed
CAS No. 114060-62-7
Molecular Formula UNKNOWN
Molecular Weight UNKNOWN
Physical Beads/particles
Color UNKNOWN
Chemical Property UNKNOWN
Customization Content/concentration customizable per client specification

Quality Control

The quality of 2-Propenoic Acid, Methyl Ester, Polymer With Diethenylbenzene, Ethenylethylbenzene And 1,7-Octadiene, Hydrolyzed is governed by its crosslinked hydrolyzed polyacrylate network, whose carboxylic acid content, crosslink density and bead morphology directly affect ion exchange, adsorption and separation performance.

Differentiated QC focus Structure, application impact, detection and control
Carboxylic acid content Carboxylic acid groups generated by hydrolysis provide the cation exchange capacity of the polymer. In water processing and demineralization, low acid content reduces exchange capacity, while excessive or uneven hydrolysis can alter swelling and kinetics. Set an agreed specification range for total exchange capacity, control hydrolysis conditions, and trend capacity against exchange performance. Test by acid-base titration of the ion exchange capacity.
Degree of hydrolysis Residual methyl ester groups indicate incomplete hydrolysis and reduce the number of functional acid sites. In ion exchange and chromatographic media, incomplete hydrolysis lowers capacity and can cause inconsistent retention behavior. Monitor hydrolysis conversion and set limits on residual ester content. Test by FTIR for ester and carboxylate bands or by saponification value determination.
Crosslink density Diethenylbenzene-derived crosslinks determine network rigidity, porosity and swelling. In column operation, low crosslinking can cause excessive swelling and pressure drop, while high crosslinking can reduce accessible capacity and kinetics. Control crosslinker level and set specification limits on swelling ratio. Test by solvent swelling measurement and, where applicable, mercury or nitrogen porosimetry.
Bead size and particle distribution The product is supplied as beads or particles; bead size distribution affects flow, pressure drop and mass transfer in packed beds. In fixed-bed and column applications, fines or oversized beads can cause channeling or high pressure drop. Set agreed sieve fractions, include classification during production, and inspect lots for fines. Test by sieve analysis or laser diffraction.
Moisture content The polymer can retain water within its porous network, and moisture affects weight-based capacity calculations and storage stability. In ion exchange media, variable moisture can cause inconsistent exchange capacity per unit weight and handling difficulties. Set specification limits on water content and control drying and packaging conditions. Test by Karl Fischer titration or loss-on-drying.
Extractables and soluble fractions Residual soluble polymer, unreacted monomers or hydrolysis by-products can leach into processed fluids. In water processing and chromatographic separation, extractables can contaminate product streams and affect separation performance. Control washing steps and set limits on extractable content. Test by extraction followed by gravimetric or spectroscopic determination.
Swelling behavior The hydrolyzed network swells in aqueous media, and swelling affects bed volume, pressure drop and mechanical stability. In column operation, excessive swelling can cause bed expansion and resin degradation. Set specification limits on swelling ratio and correlate with crosslink density. Test by measuring volume change in water under defined conditions.

Batch release, COA and traceability. Each batch is released only when it conforms to the agreed specification. The Certificate of Analysis (COA) records the actual analytical methods and results for that released batch. Batch identity and results remain traceable, with lot trending used where it supports consistency review.

Storage

  • Storage conditions: Store in a cool, dry, well-ventilated area. Keep containers tightly closed when not in use.
  • Secure storage: Store in a secure, designated area with access limited to authorized personnel.
  • Incompatible materials: Keep away from strong oxidizers.
  • Handling precautions: Avoid breathing dust. Use only in a well-ventilated area. Wear protective gloves, protective clothing, eye protection, and face protection. Wash hands thoroughly after handling.
  • Waste disposal: Dispose of contents and container in accordance with local, regional, national, and international regulations.
  • Reference: Refer to the Safety Data Sheet (SDS) for detailed handling and disposal information.

Complete Your RFQ

0/ 2000

why choose us

Trusted Manufacturer

With our own production facilities, we ensure consistent quality, reliable supply, and full traceability.

Rigorous Quality Assurance

Each batch undergoes strict QC, accompanied by COA, MSDS, and full compliance with international standards.

Advanced R&D Expertise

Our in-house lab drives process innovation, new product development, and tailored synthesis solutions.