

share
Copper, Aminomethylated Divinylbenzene-Ethenylethylbenzene-Styrene Polymer Edta Complexes CAS NO 114060-59-2
Unit Price:
CAS No.:114060-59-2
Grade:Customizable
Content:Customizable
Brand:Customizable
Packaging:Customizable
Description
Copper, Aminomethylated Divinylbenzene-Ethenylethylbenzene-Styrene Polymer Edta Complexes (CAS 114060-59-2) is a crosslinked styrene-divinylbenzene polymer bearing aminomethyl groups, with ethylvinylbenzene as a copolymerized component, to which ethylenediaminetetraacetic acid (EDTA) groups are attached in complex with copper. It is recorded as a bead or particle-form material, off-white in color. The polymer backbone is a rigid, crosslinked aromatic network, and the aminomethyl-EDTA functionality provides chelating sites that hold copper ions within the polymer matrix. In chelating resin and polymer-supported reagent contexts, it serves as a solid-phase metal-binding material for capturing, holding, or releasing copper ions within a fixed bed or suspended polymer system.
In fixed-bed and batch contacting operations, Copper, Aminomethylated Divinylbenzene-Ethenylethylbenzene-Styrene Polymer Edta Complexes serves as a polymer-supported chelating material during repeated sorption and regeneration cycles. The resulting resin is used in industrial water and process-stream treatment and in polymer-supported reagent applications for metal-ion binding and separation functions.
Application
- Chelating ion exchange: In chelating ion exchange, Copper, Aminomethylated Divinylbenzene-Ethenylethylbenzene-Styrene Polymer Edta Complexes serves as a polymer-supported chelating resin, where its aminomethyl-EDTA groups contribute to selective metal-ion binding. The resulting resin is used in fixed-bed columns for metal-ion capture and separation.
- Trace metal removal evaluation: In trace metal removal evaluation, Copper, Aminomethylated Divinylbenzene-Ethenylethylbenzene-Styrene Polymer Edta Complexes may be evaluated as a chelating sorbent, where its EDTA functionality supports binding studies for dissolved metal ions. This is a research evaluation context.
- Polymer-supported reagent research: In polymer-supported reagent research, Copper, Aminomethylated Divinylbenzene-Ethenylethylbenzene-Styrene Polymer Edta Complexes may be evaluated as a solid-supported copper-EDTA complex, where the immobilized complex supports studies of heterogeneous metal-mediated reactions. This is a research context.
- Water and process-stream treatment: In water and process-stream treatment, Copper, Aminomethylated Divinylbenzene-Ethenylethylbenzene-Styrene Polymer Edta Complexes serves as a chelating contactor medium, where its immobilized EDTA groups contribute to metal-ion uptake from aqueous streams. The resulting treated stream is used in industrial water conditioning.
- Metal recovery and concentration studies: In metal recovery and concentration studies, Copper, Aminomethylated Divinylbenzene-Ethenylethylbenzene-Styrene Polymer Edta Complexes may be examined as a chelating resin for sorption and elution behavior, where its chelating sites support metal-ion uptake and release studies. This is a research context.
Basic Information
| Property | Value |
|---|---|
| Product Name | Copper, Aminomethylated Divinylbenzene-Ethenylethylbenzene-Styrene Polymer Edta Complexes |
| CAS No. | 114060-59-2 |
| Molecular Formula | UNKNOWN |
| Molecular Weight | UNKNOWN |
| Physical | Beads/particles |
| Color | Off-white |
| Chemical Property | UNKNOWN |
| Customization | Content/concentration customizable per client specification |
Quality Control
The quality of Copper, Aminomethylated Divinylbenzene-Ethenylethylbenzene-Styrene Polymer Edta Complexes is governed by its crosslinked polymer matrix and its aminomethyl-EDTA copper complex functionality, which together determine metal-binding capacity and mechanical behavior in column and batch contacting.
| Differentiated QC focus | Structure, application impact, detection and control |
|---|---|
| Copper content and complex loading | Copper held by the aminomethyl-EDTA groups determines the available binding capacity of the resin. In chelating ion exchange and metal-ion capture, low or uneven copper loading can reduce capacity and cause inconsistent breakthrough behavior. Set an agreed specification range for copper content, qualify incoming complexed resin, and trend copper value against measured capacity. Test by acid digestion followed by ICP-OES or atomic absorption spectrometry. |
| Chelating group content | The aminomethyl-EDTA functionality provides the chelating sites responsible for metal-ion binding. In fixed-bed and batch contacting, insufficient or uneven functionalization can lower uptake and cause early breakthrough. Set specification limits on functional group content and correlate with capacity measurements. Test by titration of exchangeable sites or elemental analysis of nitrogen and copper. |
| Bead size distribution and mechanical strength | The crosslinked styrene-divinylbenzene matrix determines bead integrity and hydraulic behavior. In column operation, fines or weak beads can cause pressure drop, channeling, and resin loss. Use agreed bead size ranges, screen or sieve fractions, and check resistance to attrition. Test by sieve analysis and by wet attrition or crush testing where applicable. |
| Moisture content | Water retained in the porous polymer affects weighing, capacity calculation, and handling behavior. In batch and column use, variable moisture can cause inconsistent dosing and capacity results. Set specification limits on water content and standardize drying or equilibration before testing. Test by Karl Fischer titration or loss on drying. |
| Swelling and volume change | The crosslinked polymer can change volume with solvent and ionic environment. In packed columns, excessive swelling can raise back pressure or damage the bed. Qualify swelling behavior in the intended medium and set limits on volume change. Test by measuring settled or packed bed volume in relevant media. |
| Extractables and leachable organics | Residual monomers, solvents, or low-molecular-weight species can leach from the polymer. In water and process-stream treatment, extractables can contaminate the treated stream. Include washing steps, set limits on extractable matter, and check rinse water quality. Test by solvent extraction followed by gravimetric or chromatographic analysis. |
| Color and appearance | The material is recorded as off-white beads or particles; discoloration can indicate oxidation or contamination. In visible bed applications, color change can signal quality variation. Set agreed appearance limits and inspect lots against a reference standard. Test by visual comparison against a retained reference sample. |
Batch release, COA and traceability. Each batch is released only when it conforms to the agreed specification. The Certificate of Analysis (COA) records the actual analytical methods and results for that released batch. Batch identity and results remain traceable, with lot trending used where it supports consistency review.
Storage
- Storage conditions: Store in a cool, dry, well-ventilated area. Keep containers tightly closed when not in use.
- Secure storage: Store in a secure, designated area with access limited to authorized personnel.
- Incompatible materials: Keep away from strong oxidizers and strong acids.
- Handling precautions: Avoid breathing dust or fines. Use only in a well-ventilated area. Wear protective gloves, protective clothing, eye protection, and face protection. Wash hands thoroughly after handling.
- Waste disposal: Dispose of contents and container in accordance with local, regional, national, and international regulations.
- Reference: Refer to the Safety Data Sheet (SDS) for detailed handling and disposal information.
Hot Related Products


Quaternium-18 Bentonite CAS NO 68953-58-2


Acrylonitrile, Glycidol, Tetraethylenepentamine Reaction Product CAS NO 68412-46-4


Dow Corning Fs Chemically Inert Fluid CAS NO 63148-56-1


Isothiazolinones CAS NO 26172-55-4


Aluminum Chlorohydrate CAS NO 12042-91-0


Van Gel B CAS NO 12199-37-0


Zinc Diricinoleate CAS NO 13040-19-2


Glutaraldehyde CAS NO 111-30-8


Aluminum Zirconium Trichlorohydrex Gly CAS NO 134375-99-8


1,3,5-Trimethylhexahydro-1,3,5-Triazine CAS NO 108-74-7


Pentaerythrityl Tetrastearate CAS NO 115-83-3


1,3-Dichloro-5,5-Dimethylhydantoin CAS NO 118-52-5


Isolan Powder(Content2%-20%) CAS NO 119-38-0


Diallyl Phthalate CAS NO 131-17-9


Ph 800/20 CAS NO 176-02-3


Pyrithione CAS NO 1121-30-8


Dibromochloronitromethane CAS NO 1184-89-0


Hishicolin Px-2Bzc CAS NO 1224-55-1


Akton (Tm) CAS NO 1757-18-2


Tetrahydro-5-(2-Hydroxyethyl)-1,3-Bis(Hydroxymethyl)-1,3,5-Triazin-2(1H)-One CAS NO 1852-21-7
why choose us
Trusted Manufacturer
With our own production facilities, we ensure consistent quality, reliable supply, and full traceability.
Rigorous Quality Assurance
Each batch undergoes strict QC, accompanied by COA, MSDS, and full compliance with international standards.
Advanced R&D Expertise
Our in-house lab drives process innovation, new product development, and tailored synthesis solutions.






