

share
Polypropylene-Graft-Maleic Anhydride CAS NO 107001-49-0
Unit Price:
CAS No.:107001-49-0
Grade:Customizable
Content:Customizable
Brand:Customizable
Packaging:Customizable
Description
Polypropylene-Graft-Maleic Anhydride (CAS 107001-49-0) is a functionalized polypropylene in which maleic anhydride units are grafted onto a polypropylene backbone. It is supplied as white pellets or granules and is a solid thermoplastic at ambient conditions, with the base polypropylene matrix providing melt-processability and the grafted anhydride groups providing polar functionality. Its pendant maleic anhydride groups can react with hydroxyl, amine, and epoxide functionalities and can interact with polar filler surfaces, giving it the role of a compatibilizer and coupling agent in polyolefin-based material systems. In filled and reinforced polypropylene compounds, polymer blends, and adhesion-promoting formulations, it serves as a functional polymeric additive for interfacial bonding and phase compatibility.
In glass fiber and mineral filled polypropylene compounding, Polypropylene-Graft-Maleic Anhydride serves as a coupling agent during melt compounding, where its anhydride groups react with surface hydroxyls on fillers and fibers while its polypropylene backbone provides compatibility with the matrix. The resulting compounds are used in automotive, appliance, and industrial molded parts for improved mechanical strength and dimensional stability.
Application
- Glass fiber reinforced polypropylene: In glass fiber reinforced polypropylene compounding, Polypropylene-Graft-Maleic Anhydride serves as a coupling agent, where its maleic anhydride groups react with silanol groups on the glass surface and its polypropylene backbone entangles with the matrix. The resulting compound is used in automotive and industrial molded components for improved tensile and flexural strength.
- Mineral filled polypropylene: In mineral filled polypropylene compounds, Polypropylene-Graft-Maleic Anhydride serves as an interfacial compatibilizer, where its anhydride functionality interacts with hydroxyl-bearing filler surfaces such as talc or calcium carbonate. The resulting compound is used in molded parts requiring improved stiffness and impact balance.
- Polymer blend compatibilization: In polypropylene blends with polar polymers such as polyamides or polyesters, Polypropylene-Graft-Maleic Anhydride serves as a compatibilizer, where its anhydride groups react with terminal amine or hydroxyl groups of the polar phase. The resulting blends are used in engineering components requiring combined property profiles.
- Adhesion promotion in multilayer structures: In polypropylene-based multilayer films and coated structures, Polypropylene-Graft-Maleic Anhydride serves as a tie-layer component, where its anhydride groups promote adhesion to polar substrates such as polyamide, ethylene vinyl alcohol, or metal surfaces. The resulting structures are used in packaging and industrial laminates.
- Filled cable and wire compounds: In halogen-free filled cable compounds, Polypropylene-Graft-Maleic Anhydride serves as a coupling additive, where its anhydride groups improve filler dispersion and interfacial bonding in the polyolefin matrix. The resulting compounds are used in cable insulation and sheathing applications.
- Wood-plastic and natural fiber composites: In natural fiber reinforced polyolefin composites, Polypropylene-Graft-Maleic Anhydride serves as a coupling agent, where its anhydride groups react with hydroxyl groups on cellulose fibers. The resulting composites are used in decking, automotive interior, and building profiles.
- Polymer modification research: In polyolefin functionalization research, Polypropylene-Graft-Maleic Anhydride may be evaluated as a reactive polymeric modifier, where its grafted anhydride groups support studies of grafting efficiency and interfacial reaction. This is a research evaluation context.
Basic Information
| Property | Value |
|---|---|
| Product Name | Polypropylene-Graft-Maleic Anhydride |
| CAS No. | 107001-49-0 |
| Molecular Formula | UNKNOWN |
| Molecular Weight | UNKNOWN |
| Physical | Pellets/granules |
| Color | White |
| Chemical Property | UNKNOWN |
| Customization | Content/concentration customizable per client specification |
Quality Control
The quality of Polypropylene-Graft-Maleic Anhydride is governed by its grafted maleic anhydride content and the polypropylene carrier, which together determine coupling efficiency and compatibility in filled, reinforced, and blended polyolefin systems.
| Differentiated QC focus | Structure, application impact, detection and control |
|---|---|
| Graft content (maleic anhydride) | The grafted anhydride content determines the number of reactive sites available for coupling with fillers, fibers, and polar polymers. In glass fiber reinforced and mineral filled polypropylene, low graft content can reduce interfacial bonding and mechanical strength, while excessive graft content can affect flow and cause processing issues. Set an agreed specification range for graft content and trend it against mechanical performance in compounded samples. Test by titration of the anhydride groups or by FTIR with calibration against known standards. |
| Graft distribution and homogeneity | Uneven distribution of maleic anhydride grafts along and across the polypropylene chains can cause inconsistent coupling performance within a batch. In filled compounds and blends, inhomogeneous grafting can lead to localized weak interfaces and variable mechanical results. Control through qualified grafting processes and lot-to-lot comparison of spectroscopic or thermal signatures. Test by FTIR mapping or by fractionation combined with spectroscopic analysis where required. |
| Melt flow and molecular weight | The polypropylene carrier's molecular weight and the grafting process affect melt viscosity and flow behavior. In compounding and molding, melt flow affects dispersion of fillers, fiber wetting, and processability; a shifted melt flow can cause poor mixing or surface defects. Set an agreed melt flow rate range and correlate with compounding trials. Test by melt flow rate measurement under specified conditions. |
| Volatile content and residual by-products | Residual maleic anhydride monomer, grafting by-products, or moisture can be present after the grafting process. In compounding, volatiles can cause bubbles, voids, odor, or corrosion of processing equipment. Define devolatilization steps and set limits on volatile content. Test by thermogravimetric analysis, oven volatilization, or headspace GC for specific residuals. |
| Color and pellet appearance | The product is supplied as white pellets; discoloration can indicate oxidation, thermal degradation, or contamination. In visible molded parts, color deviation can affect appearance. Set agreed color limits and protect from excessive heat during storage and processing. Test by visual comparison against a standard or colorimetry. |
| Contamination and foreign particulates | Foreign particulates or crosslinked gel particles can arise from handling, packaging, or process upsets. In thin-wall moldings and fiber-reinforced compounds, particulates can create surface defects or stress concentrations. Include filtration or screening during production and inspect lots intended for demanding applications. Test by visual inspection, sieving, or microscopic examination. |
Batch release, COA and traceability. Each batch is released only when it conforms to the agreed specification. The Certificate of Analysis (COA) records the actual analytical methods and results for that released batch. Batch identity and results remain traceable, with lot trending used where it supports consistency review.
Storage
- Storage conditions: Store in a cool, dry, well-ventilated area. Keep containers tightly closed when not in use.
- Secure storage: Store in a secure, designated area with access limited to authorized personnel.
- Incompatible materials: Keep away from strong oxidizers and sources of ignition.
- Handling precautions: Avoid breathing dust. Use only in a well-ventilated area. Wear protective gloves, protective clothing, eye protection, and face protection. Wash hands thoroughly after handling.
- Waste disposal: Dispose of contents and container in accordance with local, regional, national, and international regulations.
- Reference: Refer to the Safety Data Sheet (SDS) for detailed handling and disposal information.
Hot Related Products


Poly(Vinyl Methyl Ether) CAS NO 9003-09-2


Glycerin Rosin Ester CAS NO 8050-31-5


Polystyrene CAS NO 9003-53-6


Urea Formaldehyde CAS NO 9011-05-6


Poly(Methyl Methacrylate) CAS NO 9011-14-7


Poly(Propylene-Co-Ethylene) CAS NO 9010-79-1


Poly(Vinylidene Fluoride-Co-Hexafluoropropylene) CAS NO 9011-17-0


Formaldehyde, Polymer With (Chloromethyl)Oxirane And Phenol CAS NO 9003-36-5


Polyethyleneimine CAS NO 9002-98-6


Poly(Vinyl Acetate) CAS NO 9003-20-7


Poly(Vinyl Chloride-Co-Vinyl Acetate) CAS NO 9003-22-9


Polybutenes CAS NO 9003-29-6


Poly(Sodium 4-Styrenesulfonate) CAS NO 9003-59-2


Poly(n-Butyl Methacrylate) CAS NO 9003-63-8


Fatty Acids, C18-Unsatd., Dimers, Polymers With Ethylenediamine CAS NO 68650-50-0


2-Propenenitrile-1,3-Butadiene, Carboxy Terminated-Bisphenol A Diglycidyl Ether Polymer CAS NO 68648-83-9


Polybutadiene, Dicarboxy Terminated CAS NO 68891-79-2


Hydroxyl-Terminated Polybutadiene CAS NO 69102-90-5


Poly(Isobornyl Methacrylate) CAS NO 64114-51-8


Polysuccinimide CAS NO 5608-40-6
why choose us
Trusted Manufacturer
With our own production facilities, we ensure consistent quality, reliable supply, and full traceability.
Rigorous Quality Assurance
Each batch undergoes strict QC, accompanied by COA, MSDS, and full compliance with international standards.
Advanced R&D Expertise
Our in-house lab drives process innovation, new product development, and tailored synthesis solutions.






