share

Sodium Percarbonate CAS NO 14455-47-1


Unit Price:

CAS No.:14455-47-1

Grade:Customizable

Content:Customizable

Brand:Customizable

Packaging:Customizable

Description

Sodium Percarbonate (CAS 14455-47-1) is a solid peroxygen compound described in the source record as a white crystalline granular material. It is a solid at ambient conditions and is handled as a granular product in packaging and dispensing operations. The material is a carbonate-based peroxygen compound, and its characteristic feature is the release of hydrogen peroxide when it is dissolved or contacted with water, which gives it an oxidative function in aqueous systems. In aqueous formulation and processing contexts, it serves as a solid source of hydrogen peroxide for oxidative bleaching, oxidation and oxygen-release functions, where a dry, granular peroxygen feed is preferred over liquid hydrogen peroxide.

In aqueous formulation and processing, Sodium Percarbonate serves as a solid peroxygen source that is dissolved or dispersed into the aqueous system, where it releases hydrogen peroxide for the intended oxidative function. The resulting aqueous oxidative liquor is used in bleaching, oxidation and oxygen-release applications where a granular solid peroxygen feed is more convenient to handle than liquid hydrogen peroxide.

Application

  • Oxidative bleaching formulation: In aqueous bleaching formulations, Sodium Percarbonate serves as a solid peroxygen source, where its release of hydrogen peroxide on dissolution provides the oxidative species. The resulting aqueous bleaching liquor is used in textile, pulp and general industrial bleaching operations.
  • Oxidation reactions in aqueous media: In aqueous oxidation processing, Sodium Percarbonate serves as an oxidative reagent, where the hydrogen peroxide released on dissolution acts as the oxidant. The resulting oxidized process stream is used in industrial oxidation steps where a solid peroxygen feed is preferred.
  • Oxygen-release formulation: In formulations requiring controlled oxygen release, Sodium Percarbonate serves as the peroxygen component, where its dissolution releases hydrogen peroxide and subsequently oxygen. The resulting formulation is used in applications where a granular solid oxygen source is required.
  • Laboratory oxidation studies: In laboratory oxidation studies, Sodium Percarbonate may be evaluated as a convenient solid peroxygen oxidant, where its dissolution provides hydrogen peroxide in situ. This is a research evaluation context.
  • Solid peroxygen handling and dosing: In dry-blend and dosing operations, Sodium Percarbonate serves as a granular peroxygen component, where its solid granular form supports weighing and dispensing into formulations. The resulting blends are used in industrial processing where a dry peroxygen feed is required.

Basic Information

Property Value
Product Name Sodium Percarbonate
CAS No. 14455-47-1
Molecular Formula UNKNOWN
Molecular Weight 314.02 g/mol
Physical Crystalline granules
Color White
Chemical Property UNKNOWN
Customization Content/concentration customizable per client specification

Quality Control

The quality of Sodium Percarbonate is governed by its peroxygen content and its behavior as a granular solid, which together determine the oxidative capacity delivered on dissolution and the handling behavior of the material.

Differentiated QC focus Structure, application impact, detection and control
Peroxygen content The available hydrogen peroxide released on dissolution is the functional basis of the material. In bleaching and oxidation applications, a low peroxygen content reduces oxidative capacity and requires higher dosing, while an excessive or unstable value can cause over-oxidation or inconsistent results. Set an agreed specification range for peroxygen content and trend it against application performance. Test by permanganate or cerimetric titration of the released hydrogen peroxide.
Moisture and water content The material is a solid peroxygen compound, and absorbed water can promote decomposition with loss of active oxygen. In storage and dry-blend operations, elevated moisture can reduce peroxygen content, cause caking and generate gas in closed containers. Control packaging and storage conditions and set limits on water content. Test by Karl Fischer titration or loss-on-drying under conditions that avoid decomposition.
Granular size and particle distribution The granular form determines flow, dosing and dissolution behavior. In dry-blend and dosing operations, an off-specification particle distribution can cause segregation, uneven dosing or slow dissolution. Set an agreed particle-size distribution and check it against the application requirement. Test by sieve analysis.
Appearance and color The material is described as white; discoloration can indicate decomposition or contamination. In bleaching and other appearance-sensitive applications, color deviation can affect the finished product. Set agreed color limits and protect the material from heat and moisture. Test by visual comparison against a standard.
Thermal stability and decomposition behavior Solid peroxygen compounds can decompose with gas release when exposed to heat or moisture. In storage and processing, decomposition can cause pressure build-up in closed containers and loss of active content. Control storage temperature and container venting, and monitor stability. Test by accelerated stability or gas-evolution testing under defined conditions.

Batch release, COA and traceability. Each batch is released only when it conforms to the agreed specification. The Certificate of Analysis (COA) records the actual analytical methods and results for that released batch. Batch identity and results remain traceable, with lot trending used where it supports consistency review.

Storage

  • Storage conditions: Store in a cool, dry, well-ventilated area. Keep containers tightly closed when not in use.
  • Secure storage: Store in a secure, designated area with access limited to authorized personnel.
  • Incompatible materials: Keep away from acids, reducing agents, combustible materials and sources of heat.
  • Handling precautions: Avoid breathing dust. Use only in a well-ventilated area. Wear protective gloves, protective clothing, eye protection, and face protection. Wash hands thoroughly after handling.
  • Waste disposal: Dispose of contents and container in accordance with local, regional, national, and international regulations.
  • Reference: Refer to the Safety Data Sheet (SDS) for detailed handling and disposal information.

Complete Your RFQ

0/ 2000
Hot Related Products

why choose us

Trusted Manufacturer

With our own production facilities, we ensure consistent quality, reliable supply, and full traceability.

Rigorous Quality Assurance

Each batch undergoes strict QC, accompanied by COA, MSDS, and full compliance with international standards.

Advanced R&D Expertise

Our in-house lab drives process innovation, new product development, and tailored synthesis solutions.