share

Dechlorane 603 CAS NO 13560-92-4


Unit Price:

CAS No.:13560-92-4

Grade:Customizable

Content:Customizable

Brand:Customizable

Packaging:Customizable

Description

Dechlorane 603 (CAS 13560-92-4) is a chlorinated polycyclic hydrocarbon compound used as a flame retardant additive. It is a solid and is white in appearance. Its highly chlorinated, rigid polycyclic structure is associated with high chlorine content and thermal stability, which supports its role as a halogenated flame retardant additive in polymer systems. In polymer and elastomer formulation, it serves as a chlorinated flame retardant component for reducing flammability in compounded materials.

In polymer compounding and elastomer formulation, Dechlorane 603 is incorporated as a chlorinated flame retardant additive during batch mixing and repeated manufacturing of filled polymer compounds. The resulting compounds are used in wire and cable jacketing, molded polymer parts, and construction-related polymer components where flame retardancy is a required material function.

Application

  • Polymer flame retardancy: In polymer compounding, Dechlorane 603 serves as a chlorinated flame retardant additive, where its high chlorine content contributes to flame inhibition in the condensed and gas phases. The resulting compounds are used in molded and extruded polymer parts requiring flame retardancy.
  • Elastomer and rubber compounds: In elastomer and rubber formulation, Dechlorane 603 serves as a halogenated flame retardant additive, where its thermal stability supports incorporation into rubber mixing and vulcanization processes. The resulting elastomer compounds are used in industrial rubber components and cable-related parts.
  • Wire and cable compounds: In wire and cable compound formulation, Dechlorane 603 serves as a flame retardant additive, where its chlorinated structure contributes to reduced flammability of the insulation or jacketing compound. The resulting compounds are used in cable jacketing and insulation constructions.
  • Thermoplastic and thermoset systems: In thermoplastic and thermoset formulation, Dechlorane 603 serves as a flame retardant additive, where its thermal stability supports melt processing and curing operations. The resulting materials are used in electrical and construction polymer components.
  • Construction polymer components: In construction polymer formulation, Dechlorane 603 serves as a flame retardant additive, where its chlorinated structure contributes to flame retardancy in the finished compound. The resulting components are used in building and infrastructure polymer parts.
  • Flame retardant formulation research: In flame retardant formulation research, Dechlorane 603 may be evaluated as a chlorinated polycyclic additive, where its high chlorine content supports studies of flame inhibition behavior in polymer systems.

Basic Information

Property Value
Product Name Dechlorane 603
CAS No. 13560-92-4
Molecular Formula UNKNOWN
Molecular Weight 653.66 g/mol
Physical Solid
Color White
Chemical Property UNKNOWN
Customization Content/concentration customizable per client specification

Quality Control

The quality of Dechlorane 603 is governed by its identity as a chlorinated polycyclic flame retardant additive, where chlorine content and thermal stability directly affect flame retardancy and processing behavior in polymer compounds.

Differentiated QC focus Structure, application impact, detection and control
Identity and chlorine content The chlorinated polycyclic structure determines the flame retardant function. In polymer compounding, variation in chlorine content affects flame inhibition efficiency and loading requirements. Confirm identity and chlorine content against agreed specifications using elemental analysis or combustion ion chromatography, and trend results across lots.
Thermal stability Thermal stability affects survival of the additive through melt processing and curing. In thermoplastic and thermoset systems, insufficient stability can cause decomposition, discoloration, or loss of flame retardancy. Assess thermal behavior by thermogravimetric analysis and correlate with processing temperature windows.
Volatile matter and moisture Residual volatiles or moisture can cause voids, surface defects, or processing instability. In wire and cable and molded compounds, these defects affect appearance and electrical performance. Set limits on volatile content and moisture, and control drying and packaging conditions.
Particle size and dispersion Particle size and agglomeration affect dispersion in the polymer matrix. In filled compounds, poor dispersion can cause uneven flame retardancy and surface defects. Control particle size distribution and dispersion quality, and verify by sieving or microscopy where relevant.
Color and appearance The product is described as white; color development can indicate contamination or degradation. In light-colored or appearance-critical compounds, color shift affects the finished part. Set agreed color limits and protect from contamination during storage and handling.
Trace impurities Residual impurities from manufacture can affect thermal stability and electrical properties. In electrical and cable applications, impurities can influence insulation performance. Qualify raw materials and set limits on relevant impurities where the application requires.

Batch release, COA and traceability. Each batch is released only when it conforms to the agreed specification. The Certificate of Analysis (COA) records the actual analytical methods and results for that released batch. Batch identity and results remain traceable, with lot trending used where it supports consistency review.

Storage

  • Storage conditions: Store in a cool, dry, well-ventilated area. Keep containers tightly closed when not in use.
  • Secure storage: Store in a secure, designated area with access limited to authorized personnel.
  • Incompatible materials: Keep away from strong oxidizers and sources of ignition.
  • Handling precautions: Avoid breathing dust. Use only in a well-ventilated area. Wear protective gloves, protective clothing, eye protection, and face protection. Wash hands thoroughly after handling.
  • Waste disposal: Dispose of contents and container in accordance with local, regional, national, and international regulations.
  • Reference: Refer to the Safety Data Sheet (SDS) for detailed handling and disposal information.

Complete Your RFQ

0/ 2000

why choose us

Trusted Manufacturer

With our own production facilities, we ensure consistent quality, reliable supply, and full traceability.

Rigorous Quality Assurance

Each batch undergoes strict QC, accompanied by COA, MSDS, and full compliance with international standards.

Advanced R&D Expertise

Our in-house lab drives process innovation, new product development, and tailored synthesis solutions.