share

Tetrakis(2-Hydroxyethyl)Ammonium Chloride CAS NO 13269-66-4


Unit Price:

CAS No.:13269-66-4

Grade:Customizable

Content:Customizable

Brand:Customizable

Packaging:Customizable

Description

Tetrakis(2-Hydroxyethyl)Ammonium Chloride (CAS 13269-66-4) is a quaternary ammonium chloride in which the nitrogen center carries four 2-hydroxyethyl substituents. It is recorded as a viscous, colorless liquid. The combination of a permanent cationic quaternary ammonium center with four terminal hydroxyl groups gives the molecule both ionic character and hydrogen-bonding capability, so it is expected to be water-compatible and to orient at interfaces in aqueous and polar media. In cationic surfactant and surface-processing formulation, it serves as a cationic functional component for charge control and surface interaction.

In aqueous and polar formulation systems, Tetrakis(2-Hydroxyethyl)Ammonium Chloride serves as a cationic charge-bearing component during batch compounding of surfactant, antistatic, and surface-processing preparations. The resulting formulations are used in industrial cleaning, metal surface processing, and polymer processing for charge dissipation and surface conditioning functions.

Application

  • Cationic surfactant formulation: In aqueous surfactant formulation, Tetrakis(2-Hydroxyethyl)Ammonium Chloride serves as a cationic component, where its permanently charged quaternary ammonium center contributes to interfacial adsorption and charge modification. The resulting formulation is used in industrial cleaning and surface-processing products.
  • Antistatic formulation for polymers and textiles: In antistatic formulation, Tetrakis(2-Hydroxyethyl)Ammonium Chloride serves as a cationic antistatic component, where its quaternary ammonium group contributes to surface conductivity and static charge dissipation. The resulting processing is used in polymer and textile processing.
  • Conductivity adjustment in aqueous systems: In aqueous electrolyte and formulation systems, Tetrakis(2-Hydroxyethyl)Ammonium Chloride serves as a cationic salt component, where its ionic character contributes to conductivity adjustment. The resulting system is used in industrial process formulations.
  • Corrosion-inhibition formulation research: In corrosion-inhibition formulation research, Tetrakis(2-Hydroxyethyl)Ammonium Chloride may be evaluated as a cationic inhibitor component, where its quaternary ammonium center and hydroxyl groups support adsorption studies on metal surfaces. This is a formulation research context.
  • Metal surface processing: In metal surface processing, Tetrakis(2-Hydroxyethyl)Ammonium Chloride serves as a cationic additive, where its surface-active quaternary ammonium structure contributes to surface conditioning. The resulting processing bath is used in industrial metal processing.
  • Hydroxyl-functional quaternary ammonium chemistry: In quaternary ammonium chemistry, Tetrakis(2-Hydroxyethyl)Ammonium Chloride may be evaluated as a hydroxyl-functional cationic building block, where its four terminal hydroxyl groups provide sites for further derivatization. This is a laboratory synthesis research context.

Basic Information

Property Value
Product Name Tetrakis(2-Hydroxyethyl)Ammonium Chloride
CAS No. 13269-66-4
Molecular Formula UNKNOWN
Molecular Weight 229.70 g/mol
Physical Viscous liquid
Color Colorless
Chemical Property UNKNOWN
Customization Content/concentration customizable per client specification

Quality Control

The quality of Tetrakis(2-Hydroxyethyl)Ammonium Chloride is governed by its quaternary ammonium identity and its four hydroxyethyl substituents, which together determine ionic behavior, water compatibility, and performance in surfactant, antistatic, and surface-processing formulations.

Differentiated QC focus Structure, application impact, detection and control
Quaternary ammonium identity and cationic content The permanently charged quaternary ammonium center provides the cationic character that drives interfacial adsorption and charge modification in surfactant and antistatic formulations. A low cationic content weakens surface activity and charge dissipation, while inconsistent content causes batch-to-batch variation in formulation performance. Confirm identity and cationic content against an agreed specification, and trend results across lots. Test by titration of the quaternary ammonium cation with a suitable anionic titrant, or by ion chromatography where appropriate.
Hydroxyethyl substitution and hydroxyl value Four terminal hydroxyl groups give the molecule hydrogen-bonding capability and sites for further derivatization. Incomplete hydroxyethyl substitution changes the hydrophilic-lipophilic balance and can shift solubility and interfacial behavior in aqueous formulations. Set an agreed hydroxyl value or substitution range and correlate it with solubility and surface activity. Test by hydroxyl value titration or by 1H NMR integration of the hydroxyethyl signals.
Water content The product is recorded as hygroscopic, so absorbed water can dilute the active cationic content and alter conductivity and dosage response in aqueous formulations. Define moisture-controlled packaging and storage, set a water content limit, and check water content before release. Test by Karl Fischer titration.
pH of aqueous solution The pH of the aqueous product affects the ionization state of formulation components and the stability of the cationic species in surfactant and surface-processing baths. Shifted pH can reduce performance or promote degradation during storage. Set an agreed pH range for a defined aqueous dilution and monitor it per lot. Test by potentiometric pH measurement on a standard dilution.
Chloride counter-ion content Chloride is the counter-ion balancing the quaternary ammonium cation; its level reflects the stoichiometry of the salt. Deviations can indicate residual inorganic chloride or incomplete quaternization, which affect ionic strength and conductivity in formulation. Set an agreed chloride range and trend it against cationic content. Test by argentometric titration or ion chromatography.
Color and clarity The product is recorded as a colorless liquid; color development can indicate thermal degradation, oxidation, or contamination during storage or handling. In surface-processing and cleaning formulations, color and haze affect appearance and can signal quality loss. Set agreed color limits and protect from heat and light. Test by visual comparison against a standard or by colorimetry.
Residual amine and low-molecular-weight species Residual tertiary amine or low-molecular-weight by-products from quaternization can remain in the product and affect odor, pH, and surface activity. Elevated residuals can reduce formulation consistency and contribute to corrosion or foaming variation. Qualify raw materials and process steps, and set limits where the application requires. Test by GC or HPLC with an appropriate detection method.

Batch release, COA and traceability. Each batch is released only when it conforms to the agreed specification. The Certificate of Analysis (COA) records the actual analytical methods and results for that released batch. Batch identity and results remain traceable, with lot trending used where it supports consistency review.

Storage

  • Storage conditions: Store in a cool, dry, well-ventilated area. Keep containers tightly closed when not in use to limit moisture uptake.
  • Secure storage: Store in a secure, designated area with access limited to authorized personnel.
  • Incompatible materials: Keep away from strong oxidizing agents and strong acids.
  • Handling precautions: Avoid breathing vapors or mist. Use only in a well-ventilated area. Wear protective gloves, protective clothing, eye protection, and face protection. Wash hands thoroughly after handling.
  • Waste disposal: Dispose of contents and container in accordance with local, regional, national, and international regulations.
  • Reference: Refer to the Safety Data Sheet (SDS) for detailed handling and disposal information.

Complete Your RFQ

0/ 2000

why choose us

Trusted Manufacturer

With our own production facilities, we ensure consistent quality, reliable supply, and full traceability.

Rigorous Quality Assurance

Each batch undergoes strict QC, accompanied by COA, MSDS, and full compliance with international standards.

Advanced R&D Expertise

Our in-house lab drives process innovation, new product development, and tailored synthesis solutions.